DataPro RJ45 (f/f)

SPD for use in personal computer or server networks, etc. (Cat. 5 / class D).

  • RJ45 connector on both sides of the device;
  • suitable for both shielded and unshielded cables;
  • connecting cable is included;
  • compatible with 10Base T / 100Base T;
  • test standard: IEC 61643-21 / EN 61643-21;
  • IEC/EN category: C1/C2/C3.

DataPro RJ45 PoE Alu

SPD for use in LAN data networks (Cat 5e) with a transfer rate of up to 1 Gbit/s. The SPD is intended to protect devices in a PoE system.

  • RJ45 connector on both sides of the device;
  • suitable for both shielded and unshielded cables;
  • connecting cable is included;
  • compatible with 10Base-T /100BASE-T/100BASE T;
  • test standard: IEC 61643-21 / EN 61643-21;
  • IEC/EN category: C1/C2/C3.

DataPro x8RJ45-19"

A compact module consisting several SPDs for use in data networks (Cat. 5 / class D). Each module includes 1 to 6 panels, protecting eight RJ45 ports each.

  • Mountable in a 19" rack
  • shielded metal housing;
  • protects 8 to 48 RJ45 ports;
  • compatible with 10Base T / 100Base T;
  • test standard: IEC 61643-21 / EN 61643-21;
  • IEC/EN category: C1/C2/C3.

DataPro 10LSA (RTC)

SPD for 10 conductor pairs, applied in LSA modules. Designed for the protection of telecommunication systems.

  • Protection circuit for 10 line pairs;
  • combined SPD for rough and fine protection;
  • protection against longitudinal and transverse surge;
  • DP10LSA-PTC versions are equipped with PTC thermistors;
  • nominal discharge current 5 kA (8/20 microseconds);
  • suitable for use in AC and DC grids;
  • test standard: IEC 61643-21 / EN 61643-21;
  • IEC/EN category: C1+C2.

DataPro-Koax-8V-BNC 75 Оhm

DataPro-Koax-8V-BNC 75 Ohm surge protection device is designed to protect sensitive coaxial systems or devices against lightning-induced surges.

  • two-level arrangement for the "rough" and "fine" protection of equipment is implemented using the combination of a gas discharger and diodes;
  • rough protection is able to drain current of up to 10 kA (8/20 microseconds);
  • diodes provide for low residual voltage;
  • the device is equipped with an EMI filter;
  • shielded metal case;
  • BNC type connector, male-female;
  • absolute galvanic isolation of the cable core and sheath from the grounding device eliminates the flow of equalizing currents through the coaxial cable.

PheeNet LA-6GWGT

PheeNet LA-6GW/GT is a lightning protection device for access point coaxial transmission lines (from the antenna side) designed to protect telecommunication equipment against the damage of electronic circuits from surge caused by a lightning discharge.