ZANDZ lightning protection kit for a single-family house with a complex roof with at least two chimney pipes

free shipping ground and lightning protection 2017

Article:ZZ-200-004

 lightning protection kit for a single-family house

ZANDZZZ-200-004 ready-made lightning protection kit for a single-family house with a complex roof with at least two chimney pipes - contains everything you need to make a reliable and durable system of external lightning protection for your house.

Applicable for:
Objects of the 3rd category of lightning protection according to
RD 34.21.122-87 and to ordinary ones, according to СО 153-34.21.122-2003
The kit ensures the reliability of the system – min. 0.9.

 

Characteristics of the protected object:

  • Type of roof: complex, hip, envelope, with dormer windows, with at least two chimney pipes
  • Wall height: up to 9 m (3 fl.)
  • Ridge height: 13-14 m
  • Dimensions of a house: max. 18x18 m
  • Roofing material: natural tile (ceramic, polymer-sand, cement-sand), metal tile, slate, metal roofs (with a thickness of less than 0.5 mm - profiled flooring, folded roof), slate roofing; It is also allowed to use fire retardant materials.
 

Technical description of the system

The set of actions to ensure the necessary requirements for the lightning protection system is presented by the following solutions:

  1. Lightning protection is performed in accordance with CO 153-34.21.122-2003 "Instructions for the installation of lightning protection of buildings, structures and industrial communications" and RD 34.21.122-87" Instructions for the installation of lightning protection of buildings and structures".
  2. Lightning protection is made using two ZZ-201-004 lightning rods-masts that are mounted on ZZ-203-002 holders on chimney pipes (the distance between the legs is up to 1 m). Connection to the conductor wire is made using the ZZ-202-001 clamp. At the top of the bay window, there are installed a ridge lightning rods with a height of 2 m (GL-11521SS), that is attached by means of the GL-11525 holder.
  3. The conductor wires are made of conductor - copper-coated steel with a diameter of 8 mm, a coating thickness of 70 microns (GL-11149).
  4. Installation of conductor wires is carried out by means of GL-11747A clamp - on the roof, GL-11703A - on vertical surfaces. Clamp installation step - 0.8-1.0 m.
  5. For connection of rolled metal along the length and in the junctions, the universal GL-11551A clamp is used.
  6. All metal elements placed on the roof must be attached to the conductor wires using GL-11514 or GL-11545А clamp.
  7. The grounding device uses 3 vertical electrodes with a length of 3 m combined by a grounding conductor - a strip of steel copper-clad 30x4 mm (GL-11075). The distance from the grounding to the object is min. 1 m.
  8. Conductor wires are connected to the grounding conductor using GL-11562A clamps.
  9. Detailed installation instructions are included.
 lightning protection kit for a single-family house 2
Figure 1 - Equipment Location

 

Молниеприемник-мачта высотой 4 м (ZZ-201-004) Lightning rod - mast with the height of 4 m (ZZ-201-004)
Молниеприемник коньковый высотой 2 м (GL-1521SS) Ridge lightning rod with the height of 2 m (GL-11521SS)
Проволока омедненная стальная диаметром 8 мм (GL-11149) Copper-plated steel wire with a diameter of 8 mm (GL-11149)
Полоса омедненная стальная сечением 30x4 мм (GL-11075) Strip of copper-coated steel with a section of 30x4 mm (GL-11075)
Электрод D= 14 мм. L=3 м Electrode D=14 mm. L=3 m

 

 

Kit contents

Figure

Article

Name

Quantity

 

vertical lightning rod

 

ZZ-201-004

ZANDZ vertical lightning rod - mast vertical 4 m high (stainless steel)

2 pieces

 

Fastening for the lightning rod to the chimney

 

ZZ-203-002

ZANDZ Fastening for the lightning rod to the chimney (stainless steel)

2 pieces

 

Clamp to lightning rod for conductor wires

 

ZZ-202-001

ZANDZ Clamp to lightning rod for conductor wires (stainless steel)

2 pieces

 

 lightning rod 2 meters high for installation in threaded holders

 

GL-11521SS

GALMAR lightning rod 2 meters high for installation in threaded holders (M16; stainless steel)

2 pieces

 

Ridge holder for the lightning rod

 

GL-11525

GALMAR Ridge holder for the lightning rod (thread M16; connection of the conductor wire d10 mm; bronze)

2 pieces

 

Copper-plated wire

 

GL-11149-50

GALMAR Copper-plated wire (D 8 mm / S 50 mm2; coil 50 meters)

3 pieces

 

Clamp for connecting conductor wires

 

GL-11551A

GALMAR Clamp for connecting conductor wires (painted galvanized steel)

15 pieces

 

Clamp for the roof

 

GL-11747A

GALMAR Clamp for the roof, covered with a metal profile / profiled flooring for the conductor wire (painted galvanized steel)

120 pieces

 

Clamp to the façade

 

GL-11703A

GALMAR Clamp to the façade for the conductor wire with an elevation of 15 mm (painted galvanized steel)

30 pieces

 

Clamp for the drainpipe for conductor wire

 

GL-11545A

GALMAR Clamp for the drainpipe for conductor wire (painted galvanized steel)

5 pieces

 

Clamp - hose clamp for drain pipe for conductor wire

 

GL-11514

GALMAR Clamp - hose clamp for drain pipe for conductor wire (tinned copper)

5 pieces

 

Test clamp

 

GL-11562A

GALMAR Test clamp for connecting the "wire + strip" conductor wires (painted galvanized steel)

2 pieces

 

Grounding pin copper coated threaded

 

ZZ-001-065

ZANDZ Grounding pin copper coated threaded (D14; 1.5 m)

6 pieces

 

Coupling threaded

 

ZZ-002-061

ZANDZ Coupling threaded

4 pieces

 

Starting cap

 

ZZ-003-061

ZANDZ Starting cap

3 pieces

 

Guide head for jackhammer attachment

 

ZZ-004-060

ZANDZ Guide head for jackhammer attachment

2 pieces

 

Conductive lubricant

 

ZZ-006-000

ZANDZ Conductive lubricant

1 piece

 

Jackhammer (SDS max)

 

ZZ-008-000

ZANDZ Jackhammer (SDS max)

1 piece

 

Clamp for connecting the conductor

 

ZZ-005-064

ZANDZ Clamp for connecting the conductor (up to 40 mm)

4 pieces

 

Waterproofing Tape

 

ZZ-007-030

ZANDZ Waterproofing Tape

1 piece

 

Strip copper-plated steel

 

GL-11075-20

GALMAR Strip copper-plated steel (30 * 4 mm; coil 20 meters)

1 piece

 

ZANDZ Grounding Conductor

 

ZZ-500-110

ZANDZ Grounding Conductor (10m; S25; solid; with bolt cap D8)

1 piece

 

Important! Restrictions on the use of the kit

  1. The kit is applicable strictly for the specified building configuration. The type of roof, the height of the walls, the height of the ridge and the overall dimensions of your building should not exceed the values given in the description of the kit.

    If one of the dimensions of your house exceeds the specified values, you can buy additional accessories at your discretion.


  2. The calculation of the resistance of the grounding device as part of ZANDZ lightning protection system was made for objects located in regions with ordinary soil (loam, clay, sandy loam, ...). This kit is not applicable in regions with high soil resistivity.

    You can read the average values of specific resistance of various types of soil by the link.
    The reference material on this page will help you to calculate the necessary grounding device configuration.


  3. The kit is designed for the reliability of the lightning protection system, corresponding to the type of object “single-family house” (a typical object according to CO 153-34.21.122-2003). This kit is not applicable for public, industrial and other types of objects. Any of these objects may require increased reliability of the external lightning protection system.

    You can calculate the reliability of the system, as well as the probability of a lightning breakthrough, using a specialized calculation service.

 

Buy

Price of  ZZ-200-004 - 219 600,00 rubles.

 
You can also order the installation of this kit in our company service center. The cost of the service ZZ-200-004 - rubles.