Objects of the 3rd category of lightning protection according to
RD 34.21.122-87 and to ordinary, ones, according to СО 153-34.21.122-2003.
The kit ensures the reliability of the system – min. 0.9.
Characteristics of the protected object:
- Roof type: hip, hipped, with a dormer window, without chimney pipes
- Wall height: max. 9 m (3 fl.)
- Ridge height: min. 3 m above the level of the walls
- Dimensions of a house: no more than 12x12 m
- Roofing material: natural tile (ceramic, polymer-sand, cement-sand), metal tile, slate, metal roofs (with a thickness of less than 0.5 mm - profiled flooring, folded roof), slate roofing; It is also allowed to use flame-retardant materials.
Technical description of the system
The set of actions to ensure the necessary requirements for the lightning protection system is presented by the following solutions:
- Lightning protection is made in accordance with СО 153-34.21.122-2003 "Instructions for the installation of lightning protection of buildings, structures and industrial communications" and
RD 34.21.122-87 "Instructions for the installation of lightning protection of buildings and structures". - Lightning protection is carried out by means of the conductor wire system with elevations of 1 m at the edges of the roof and on the ridge. The elevation is made using GL-11149 wire. At the top of the bay window, there is a ridge lightning rod installed with a height of 2 m (GL-11521SS) that is attached by means of the GL-11525 holder.
- The conductor wires are made of conductor - copper-coated steel with a diameter of 8 mm, a coating thickness of 70 microns (GL-11149).
- Installation of conductor wires is carried out by means of a GL-11747A clamp - on the roof, GL-11703A - on vertical surfaces. Clamp installation step - 0.8-1.0 m.
- For connection of conductor wires along the length and in the junctions, the GL-11551A universal clamp is used.
- All metal elements placed on the roof must be attached to the conductor wires using the clamp GL-11514 or GL-11545А.
- The grounding device uses 3 vertical electrodes with a length of 3 m combined by a grounding conductor - a strip of steel copper-clad 30x4 mm (GL-11075). The distance from the grounding to the object is not less than 1 m.
- Conductor wires are connected to the grounding conductor using GL-11562A clamps.
- Detailed installation instructions are included.


Figure 1 - Equipment location options
| Возвышения H = 1 м | Elevations H = 1 m |
| Молниеприемник-мачта высотой 2 м (GL-11521SS) | Lightning rod - mast with the height of 2 m (GL-11521SS) |
| Проволока омедненная стальная диаметром 8 мм (GL-11149) | Copper-plated steel wire with a diameter of 8 mm (GL-11149) |
| Полоса омедненная стальная сечением 30x4 мм (GL-11075) | Strip of copper-coated steel with a section of 30x4 mm (GL-11075) |
| Электрод D= 14 мм. L=3 м | Electrode D=14 mm. L=3 m |
Kit contents
Important! Restrictions on the use of the kit
-
The kit is applicable strictly for the specified building configuration. The type of roof, the height of the walls, the height of the ridge and the overall dimensions of your building shall not exceed the values given in the description of the kit.If one of the dimensions of your house exceeds the specified values, you can buy additional accessories at your discretion.
-
The calculation of the resistance of the grounding device as part of the lightning protection system was made for objects located in regions with ordinary soil (loam, clay, sandy loam, ...). This kit is not applicable in regions with high soil resistivity.You can read the average values of specific resistance of various types of soil by the link.
The reference material on this page will help you to calculate the necessary grounding device configuration. -
The kit is designed for the reliability of the lightning protection system, corresponding to the type of object “single-family house” (a typical object according to CO 153-34.21.122-2003). This kit is not applicable for public, industrial and other types of objects. Any of these objects may require increased reliability of the external lightning protection system.You can calculate the reliability of the system, as well as the probability of a lightning breakthrough, using a specialized settlement service.