Copper-bonded threaded ground rod
D: 12 mm; 14 mm; 17 mm
L: 1,2 m; 1.5 m; 1.8 m; 2.4 m; 3m
Product items:
GL-10011 /
GL-10021 / GL-10022 /
Rod made of drawn steel, galvanically coated with pure copper (99.9%), having strong molecular adhesion to steel.
Steel rod has high tensile strength of 600 N / mm², so that it can be plugged to great depth with a breaker hammer.
The copper coating of not less than 0.250 mm thick ensures that the rod hammered into the ground is safe for at least 30 years.
The ends of the rods are threaded by rolling application method which allows to connect them to each other with the help of a coupler - to create a ground electrode of great length.
| D12 | |||||
| Rod diameter: | 11 mm | 11 mm | 11 mm | 11 mm | 11 mm |
| Thread diameter: | 12,7 mm | 12,7 mm | 12,7 mm | 12,7 mm | 12,7 mm |
| Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,0 m |
| Weight: | 1,20 kg | 1,50 kg | 1,80 kg | 2,40 kg | 3,0 kg |
| D14 | GL-10011 | ||||
| Rod diameter: | 14,2 mm | 14,2 mm | 14,2 mm | 14,2 mm | 14,2 mm |
| Thread diameter: | 16 mm | 16 mm | 16 mm | 16 mm | 16 mm |
| Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,0 m |
| Weight: | 1,50 kg | 1,90 kg | 2,30 kg | 3,12 kg | 3,8 kg |
| D17 | GL-10022 | ||||
| Rod diameter: | 17,2 mm | 17,2 mm | 17,2 mm | 17,2 mm | 17,2 mm |
| Thread diameter: | 19 mm | 19 mm | 19 mm | 19 mm | 19 mm |
| Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,1 m |
| Weight: | 2.20 kg | 2.75 kg | 3.40 kg | 4.35 kg | 5,4 kg |
Details about manufacturing and testing technology of the coating is available on a separate page.
Copper-bonded clutchless ground rod
D: 14 mm; 17 mm
L: 1,2 m; 1,5 m
Product items:
Galmar vertical copper-bonded clutchless (forge) ground rods with a clamp- sealing sleeve are made of rolled steel with electrolytic copper bonding of purity of 99.9% and thickness not less than 0.250 mm, which composes molecular and inseparable connection with the steel. The steel electrode base has a high tensile strength of 600 N / mm².
One end of the electrode is narrowed due to forging, thanks to what it retains its protective copper coating over the entire length. In addition, the narrowed end allows to immerse the grounding pin into the ground without a special tip. There is a dead hole on the other end made for the connection of rods with each other and increase of the total length.
At the junction of rods there is a stainless steel plug, which performs the sealing role and the reinforcement of the connection. Also, the plug eliminates possible deformations of the rod slot-embedded part, arising during driving it into the ground.
It is necessary to apply driving rods, transferring the striking force to the rod centre for the installation of clutchless (forge) Galmar rods.
| D14 | ||
| Rod diameter: | 14 mm | 14 mm |
| Length: | 1,21 m | 1,51 m |
| Weight: | 1,50 kg | 1,90 kg |
| D17 | GL-00086 | |
| Rod diameter: | 17 mm | 17 mm |
| Length: | 1,21 m | 1,51 m |
| Weight: | 2.20 kg | 2.75 kg |
Details about manufacturing and testing technology of the coating is available on a separate page.
Price
GL-00072 - 2 290,00 rbl. (upon request)
PriceGL-00075 - 2 320,00 rbl. (upon request)
Price GL-00086 - 3 010,00 rbl. (upon request)
PriceGL-00085 - 1 620,00 rbl. (special price)
Copper bonded threadless ground rod
D: 12 mm; 14 mm; 17 mm; 9 mm
L: 1,2 m; 1,5 m; 1,8 m; 2,4 m; 3 m
Product items:
Rod made of drawn steel, galvanically coated with pure copper (99.9%), having strong molecular adhesion to steel. Steel rod has high tensile strength of 600 N / mm², so that it can be plugged to great depth with a breaker hammer.
Rods D12, D14 and D17 have copper coating of not less than 0.250 mm thick, which ensures that the rod hammered into the ground is safe for at least 30 years. Rods D9,6 have copper coating of not less than 0.150 mm thick.
Threadless rods are connected with the help of the connecting threadless coupler to create a greater length of the ground electrode. The recommended maximum depth of the ground electrode on the base of threadless rods - 4 meters.
Supply of coppered threadless rods is carried only upon request..
| D12 | |||||
| Rod diameter: | 12 mm | 12 mm | 12 mm | 12 mm | 12 mm |
| Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,01 m |
| Weight: | 1,20 kg | 1,50 kg | 1,80 kg | 2,40 kg | 3,0 kg |
| D14 | |||||
| Rod diameter: | 14 mm | 14 mm | 14 mm | 14 mm | 14 mm |
| Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,01 m |
| Weight: | 1,50 kg | 1,90 kg | 2,3 kg | 3,12 kg | 3,8 kg |
| D17 | |||||
| Rod diameter: | 17 mm | 17 mm | 17 mm | 17 mm | 17 mm |
| Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,01 m |
| Weight: | 2,2 kg | 2,75 kg | 3,4 kg | 4,35 kg | 5,44 kg |
| D9,6 | ||
| Rod diameter: | 9,6 mm | 9,6 mm |
| Length: | 1,21 m | 1,51 m |
| Weight: | 0,65 kg | 0,83 kg |
Price
GL-00001 - 1 200,00 rbl. (upon request)
PriceGL-00003 - 1 510,00 rbl. (upon request)
PriceGL-00006 - 1 810,00 rbl. (upon request)
PriceGL-00007 - 2 410,00 rbl. (upon request)
PriceGL-00008 - 3 020,00 rbl. (upon request)Price
GL-00044 - 1 200,00 rbl. (upon request)
PriceGL-00011 - 1 510,00 rbl. (upon request)
PriceGL-00048 - 1 810,00 rbl. (upon request)
PriceGL-00013 - 2 410,00 rbl. (upon request)
PriceGL-00035 - 3 020,00 rbl. (upon request)Price
GL-00016 - 1 510,00 rbl. (upon request)
PriceGL-00019 - 1 890,00 rbl. (upon request)
PriceGL-00020 - 2 270,00 rbl. (upon request)
PriceGL-00021 - 3 020,00 rbl. (upon request)
PriceGL-00023 - 3 780,00 rbl. (upon request)Price
GL-00027 - 1 200,00 rbl. (upon request)
PriceGL-00037 - 1 510,00 rbl. (upon request)
Non-extensible copper electrode
D: 14 mm; 17 mm
L: 1 m; 1,25 m; 2 m; 3 m
Product items:
Vertical copper-bonded non-extensible Galmar electrodes are made of rolled steel with electrolytic copper plating with a purity of 99.9% and not less than 0.250 mm thick, which forms molecular and inseparable connection with the steel. The steel electrode base has a high tensile strength of 600 N / mm².
One end of the electrode is narrowed due to forging, thanks to what it retains its protective copper coating over the entire length. In addition, the narrowed end allows to immerse the electrode into the ground without a special tip.
Non-extensible electrode is not a composite electrode and is not extended by other electrodes.
Supply of non-extensible electrodes is carried out only upon request..
| D14 | ||||
| Diameter of the electrode: | 14 mm | 14 mm | 14 mm | 14 mm |
| Length: | 1,01 m | 1,51 m | 2,01 m | 3.01 m |
| Weight: | 1,20 kg | 1,80 kg | 2,40 kg | 3,80 kg |
| D17 | ||||
| Diameter of the electrode: | 17 mm | 17 mm | 17 mm | 17 mm |
| Length: | 1,01 m | 1,51 m | 2,01 m | 3,01 m |
| Weight: | 1,83 kg | 2,75 kg | 3,66 kg | 5,44 kg |
Price
GL-00038M - 1 050,00 rbl. (upon request)
PriceGL-00011M - 1 570,00 rbl. (upon request)
PriceGL-00014M - 2 100,00 rbl. (upon request)
PriceGL-00035M - 3 150,00 rbl. (upon request)
PriceGL-00064M - 1 530,00 rbl. (upon request)
PriceGL-00019M - 2 300,00 rbl. (upon request)
PriceGL-00022M - 3 060,00 rbl. (upon request)
PriceGL-00023M - 4 590,00 rbl. (upon request)