Product items:
Rod made of drawn steel, galvanically coated with pure copper (99.9%), having strong molecular adhesion to steel. Steel rod has high tensile strength of 600 N / mm², so that it can be plugged to great depth with a breaker hammer.
Rods D12, D14 and D17 have copper coating of not less than 0.250 mm thick, which ensures that the rod hammered into the ground is safe for at least 30 years. Rods D9,6 have copper coating of not less than 0.150 mm thick.
Threadless rods are connected with the help of the connecting threadless coupler to create a greater length of the ground electrode.
The recommended maximum depth of the ground electrode on the base of threadless rods - 4 meters.
Threadless rods are installed with a breaker hammer with a special adapter and a head for threadless ground rods fixed in the hole of the rod.
Supply ofа coppered threadless rods is carried only upon request..
D12 | |||||
Rod diameter: | 12 mm | 12 mm | 12 mm | 12 mm | 12 mm |
Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,01 m |
Weight: | 1,20 kg | 1,50 kg | 1,80 kg | 2,40 kg | 3,0 kg |
D14 | |||||
Rod diameter: | 14 mm | 14 mm | 14 mm | 14 mm | 14 mm |
Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,01 m |
Weight: | 1,50 kg | 1,90 kg | 2,3 kg | 3,12 kg | 3,8 kg |
D17 | |||||
Rod diameter: | 17 mm | 17 mm | 17 mm | 17 mm | 17 mm |
Length: | 1,21 m | 1,51 m | 1,81 m | 2,41 m | 3,01 m |
Weight: | 2,2 kg | 2,75 kg | 3,4 kg | 4,35 kg | 5,44 kg |
D9,6 | ||
Rod diameter: | 9,6 mm | 9,6 mm |
Length: | 1,21 m | 1,51 m |
Weight: | 0,65 kg | 0,83 kg |
Price
GL-00001 - 1 200,00 rbl. (upon request)
PriceGL-00003 - 1 510,00 rbl. (upon request)
PriceGL-00006 - 1 810,00 rbl. (upon request)
PriceGL-00007 - 2 410,00 rbl. (upon request)
PriceGL-00008 - 3 020,00 rbl. (upon request)Price
GL-00044 - 1 200,00 rbl. (upon request)
PriceGL-00011 - 1 510,00 rbl. (upon request)
PriceGL-00048 - 1 810,00 rbl. (upon request)
PriceGL-00013 - 2 410,00 rbl. (upon request)
PriceGL-00035 - 3 020,00 rbl. (upon request)Price
GL-00016 - 1 510,00 rbl. (upon request)
PriceGL-00019 - 1 890,00 rbl. (upon request)
PriceGL-00020 - 2 270,00 rbl. (upon request)
PriceGL-00021 - 3 020,00 rbl. (upon request)
PriceGL-00023 - 3 780,00 rbl. (upon request)Price
GL-00027 - 1 200,00 rbl. (upon request)
PriceGL-00037 - 1 510,00 rbl. (upon request)
Copper-bonded threadless ground rod.
![Grounding device based on copper-plated threadless rods](/files/uploads/information_16936/komplekt_zazemleniya_bezrezbovoj120x600.jpg)
Grounding device based on copper-plated threadless rods.
Copper bonding technology
The key factor in the manufacture of a high-quality ground rod is formation of a firm homogeneous copper coating of the required thickness with minimal impurity elements on a steel blank.
On a separate page "Copper-bonded steel" you will see a detailed description of the main characteristics, processes during the manufacture and test of coating.
Sketch of the rod GL-00011
![Sketch of the rod](/files/uploads/information_16936/gl_00011_eskiz.jpg)