Today, wind generator installations gain popularity as one of the most affordable and simple methods of autonomous electrification of facilities.
Wind turbines are usually installed in open areas at high altitude, in the result of what, they are particularly exposed to lightning impact. To ensure safe and reliable operation, they must be appropriately protected against overvoltage. We offer you a special offer for the protection of wind turbines.
In the functional scheme of wind power there are the following elements and circuits that require overvoltage protection:
- the main power supply;
- communication lines;
- switchboard and control cabinet;
- converter;
- generator;
- power control, measurement and automation system;
- signal lighting and weather sensors;

Generator protection
Electrical connection between the generator of wind turbines and the transformer station is most often performed by a line of voltage of 400/690 V with TN or IT grounding system. For such voltages, we offer specially designed SPDs. PowerPro BC TNC 50-440 / 690 represent surge arresters of Class 1+2, with high resistance to lightning currents (150 kA 10/350 ms). They provide a limit voltage in the main power circuit to the level of 2.5 kV.
LEUTRON also developed a proposal to provide generator protection of level II: EnerPro CST 440 (TN system) and EnerPro EC 750 FM TNC (IT-system).
Comprehensive protection scheme of a windmill installation from surges

|
|
|
|
|
|---|---|---|---|
|
![]()
|
24 V power supply (DC) Signal lines Trunk main RS 485/ |
EP D TN 24V/16A DP2x1-24V/24V-0.3 Ohm DP2x1 SDSL-Tr DP-RS 485-Tr |
LE-380-550 LE-262-424 LE-240-018 LE-370-485 |
|
![]()
|
Power supply 230/400 V |
EP C S T 275 |
LE-381-270 |
|
![]()
|
Generator stator: system 400/690 B TN system 690 IT Special solutions: |
EP C S T 440 EP WE TNC 750 NAK 600TT-100kA PP WEA Y 1000 |
LE-381-300 LE-381-706 LE-378-001 LE-377-052 |
|
![]()
|
Generator rotor: system 400/690 B TN system 690 IT Special solutions: |
EP C S T 440 EP WE TNC 750 NAK 600TT-100kA PP WEA Y 1000 |
LE-381-300 LE-381-706 LE-378-001 LE-377-052 |
|
![]()
|
Signalling line, weather sensors |
DPS 2x1 ST DPS 2x1 ... HF |
LE-261-002 LE-261-004 |
|
![]()
|
Rotor core (230/400 V power supply) Signal lines |
EP C S T 275 DPS 2x1 ST DPS 2x1 HF |
LE-381-270 LE-261-002 LE-261-004 |
|
![]()
|
Main power supply (400/690 B TN or IT) |
PP BC TNC 50-400/690 |
LE-374-504 |
|
![]()
|
Converter Special solutions: |
EP C S T 440 EP WE TNC 750 NAK 600TT-100kA PP WEA Y 1000 |
LE-381-300 LE-381-706 LE-378-001 LE-377-052 |
|
![]()
|
Switchboard and control cabinet (power supply 230/400 V) |
EP C S T 275 |
LE-381-270 |
|
![]()
|
Automation Signal lines, trunk main |
EP D TN 24V/16A DPS 2x1 ST |
LE-380-550 LE-261-002 |
|
![]()
|
Modem (power supply 230/400 V) Telecommunications lines |
EP C S T 275 DPS 2x1 ... HF DP RJ45 f/f |
LE-381-270 LE-261-004 LE-240-011 |
Individual selection
In case if your wind power generation system possesses atypical characteristics or has unique patrameters, you can always contact our technical center..
The extensive range of the SPDs we offer allows us to choose an individual protection complex that meets all the requirements of reliability and efficiency.
Purchase
You can see the current prices and acquire necessary devices for surge protection in a convenient online store on a separate page "Purchase".