Overvoltage protection in single and three-phase voltage circuits [230 / 400V] 50 Hz.
The most important characteristic of Class 1 arresters is their ability to drain Iimp lightning current (pulse form 10/350 ms).
The devices in this series are intended for installation in zones 0A-1 in accordance with the concept of protection zones (IEC 61312).
- voltage protection level Up≤4,0 and 2.5 kV;
- patented sealed gas discharger and arc control pot;
- no blow hole - it is not required to keep the permissible distance to other devices;
- lightning current limit up to 100 kA (10/350 ms);
- V-shaped connection is possible;
- no leakage currents - possible installation before the counter;
- optional remote signaling contact (FM version);
Single-pole SPD of class 1
CT-T1/1+0-350-FM
One-pole SPD designed to protect low-voltage electrical equipment
- maximum lightning impulse current (10/350 ms) Iimp: 25 k╤В╨е╨╕тХи╨░;
- limit voltage Up: not more than 2.5 kV;
SPD of class 1 for use in single-phase networks with TN neutral mode
CT-T1/2+0-350-FM
SPD for use in single-phase networks with TN neutral mode and rated voltage of 230V, 50 Hz
- maximum lightning impulse current (10/350 ms) Iimp 50 k╤В╨е╨╕тХи╨░;
- limit voltage Up not more than 2.5 kV;
PowerPro B TN
SPD for use in single-phase networks with TN neutral mode and rated voltage of 230V (50 Hz)
- maximum lightning impulse current (10/350 ms) Iimp 50 k╤В╨е╨╕тХи╨░;
- limit voltage Up not more than 4.0 kV;
SPD of class 1 for use in three-phase networks with TN-C neutral mode
CT-T1/3+0-350-FM
Combined SPD for use in three-phase networks with TN-C neutral mode and rated voltage of 230 V, 50 Hz
- maximum lightning impulse current (10/350 ms) Iimp 75 k╤В╨е╨╕тХи╨░;
- limit voltage Up not more than 2.5 kV;
PowerPro B TNC
Combined SPD for use in three-phase networks with TN-C neutral mode and rated voltage of 230/400 V (50 Hz)
- maximum lightning impulse current (10/350 ms) Iimp 50 k╤В╨е╨╕тХи╨░;
- limit voltage Up not more than 4.0 kV;
SPD of class 1 for use in three-phase networks with TN-S neutral mode
CT-T1/3+1-350-FM
SPD for use in three-phase networks with TN-S neutral mode and rated voltage of 230 V, 50 Hz
- maximum lightning impulse current (10/350 ms) Iimp 100 k╤В╨е╨╕тХи╨░;
- limit voltage Up: not more than 2.5 kV;
PowerPro B TNS
SPD for use in three-phase networks with TN-S neutral mode and rated voltage of 230/400 (400/690) V (50 Hz)
- maximum lightning impulse current (10/350 ms) Iimp 100 k╤В╨е╨╕тХи╨░;
- limit voltage Up not more than 4.0 kV;
SPD of class 1 for use in three-phase networks with TT neutral mode
PowerPro B TT
SPD for use in three-phase networks with TT neutral mode and rated voltage of 230/400 V (50 Hz)
- maximum lightning impulse current (10/350 ms) Iimp 100 k╤В╨е╨╕тХи╨░;
- limit voltage Up not more than 4.0 kV;