17.06.14 , , ,
Integrated lightning current and surge arrester Capability to drain lightning currents up to 10 kA (10/350 ms) Low protection voltage is suitable for terminal equipment protection To be used in accordance with the lightning protection zone concept at the boundaries M33 0A - 2 and higher Application of actiVsense technology automatically determines the nominal signal voltage ranging from 0 to 180V Optimally adjusts the protection voltage level to the current signal level applied at the moment Adapted protection voltage level enables you to protect the terminal equipment Flexible application One safety device for two independent signal lines Applicable for wall mounting, index of protection IP 65 Simple and easy installation and modification
DEHNbox compact integrated lightning current and surge arrester to protect information and automation systems standing out thanks to actiVsense technology. The arrester can be applied in the range from 0 to 180V with superimposed signal voltage (± 5V / 50MHz). Rated current is limited to 100mA, which is sufficient for the protecting information technology systems. actiVsense technology enables the arrester to automatically determine the applied signal voltage and adjust the protection level. Thanks to that, this arrester is suitable for systems with changing or slowly fluctuating signal levels (≤ 400Hz). [[placeholder]][[placeholder]]When there is interference, DEHNbox always has adjusted minimal residual voltage for every signal voltage that provides maximum protection for devices and systems connected to it. SPD DEHNbox available in two versions: four-pole and two-pole ones. Four-pole version for protection of 2 separate balanced interfaces, i.e. arrester automatically detects applied operating voltage to be more precise signal voltage, for each of two-wire lines, and optimally adjusts the protection voltage level for each signal line. This would allow to protect two distinct balanced interfaces using only one device, which would shorten installation time, expenditure and facilitates choice among great variety of SPDs. Two-pole version for one balanced data transmission interface is used to protect only one signal interface (1 two-wire line). Functional design of DEHNbox in plastic housing with tie-down lugs is perfect for wall mounting.
Board suitable for cable ties
DEHNbox is IP 65, so that it can be installed in specific environment, e.g. high-humidity facilities. Cable entry devices are equipped with convenient self-sealing rubber membranes which enable you to carry out installation quickly and in an easy way, as well as protect against humidity and dust penetration.
Cable wires and screen are connected in a screw-free way with spring clips.
Two separate connection clips ensure direct or indirect cable screen connection to equipotential bonding system.
The arrester is perfect for private and industrial sector for information & engineering transmission systems in such spheres as telecommunications, data bus systems or control & instrumentation equipment.
Related Articles:


