High-rise catenary wire lightning protecton - is a system of external lightning protection, in which a wire acts as a lightning rod, suspended above the object to be protected on special supports which are located at some distance from this object.
High-rise catenary wire lightning protection has several advantages in comparison to the system of rod lightning rods:
- more effective; catenary-wire lightning protection system allows to achieve the so-called negative protection angles that greatly increases the reliability of protection and reduces the number of breakouts;
- to minimize the secondary effects of lightning on the object; at the correct placement of supports, lightning current spreading zone is outside the protected area;
- it allows not to mount additional constructions on the protected object; the system supports are placed outside the protected area;
- It is the home-grown technology; all elements are produced in Russia;
- has no analogues; the system of high-rise catenary-wire lightning protection ZANDZ is a unique complex offer considering the specifics of lightning protection of hazardous facilities (such as tank farms, oil storage tanks, etc.).

ZANDZ Опора системы тросовой молниезащиты с одним узлом крепления троса (высота подвеса 15 м)
Артикул: ZZ-204-115
(пр. Россия
)
Опора выполнена из стали оцинкованной, 8-гранная, коническая. Ствол опоры в нижней части имеет фланец для крепления с фундаментом. В нижней части опора оснащена люком, который обеспечивает доступ к месту подключения заземляющего устройства. Люк закрывается крышкой, исключающей попадание атмосферных осадков и несанкционированное проникновение.
В комплект поставки входят:
- опора из граненой оцинкованной стали, 16 метров высотой;
- узел крепления троса сечением 50 мм2, размещенный на опоре на высоте 15 метров;
- анкерная закладная деталь фундамента.
Монтаж:
- на забетонированные фланцевые закладные детали фундамента;
- параметры фундамента определяются расчетом и зависят от зоны эксплуатации опор и параметров грунта;
Эксплуатационные характеристики
| Климатическое исполнение и категория размещения (в соответствии с ГОСТ 15150-69) | УХЛ.1 |
| Ветровой район в соответствии с СНиП 2.01.07-85 | до III |
| Снеговой район по СНиП 2.01.07-85 | до V |
| Предельная длина подвешиваемого троса | до 100 м |
Цена - 211 500,00 Руб. (под заказ)

ZANDZ Опора системы тросовой молниезащиты с одним узлом крепления троса (высота подвеса 20 м)
Артикул: ZZ-204-120
(пр. Россия
)
Опора выполнена из стали оцинкованной, 8-гранная, коническая. Ствол опоры в нижней части имеет фланец для крепления с фундаментом. В нижней части опора оснащена люком, который обеспечивает доступ к месту подключения заземляющего устройства. Люк закрывается крышкой, исключающей попадание атмосферных осадков и несанкционированное проникновение.
В комплект поставки входят:
- опора из граненой оцинкованной стали, 21 метров высотой;
- узел крепления троса сечением 50 мм2, размещенный на опоре на высоте 20 метров;
- анкерная закладная деталь фундамента.
Монтаж:
- на забетонированные фланцевые закладные детали фундамента;
- параметры фундамента определяются расчетом и зависят от зоны эксплуатации опор и параметров грунта;
Эксплуатационные характеристики

ZANDZ System lsupportof catenary wire lightning protection with one node of wire fixation (suspension height - 35 m)
Product item:
The support is made of galvanized steel, 8-sided, conical. The support shank has flange in the bottom part for fixation with the foundation. At the bottom of the support it is equipped with a hatch that provides access to the place of connection of the grounding device. The hatch is closed with a cover, excluding insertion of precipitation and unauthorized entry.
The supply package includes:
- the support of faceted galvanized steel, 36.5 meters high;
- the mode of wire fixation with the section of 50 mm2placed on the support at the height of 35 meters;
- anchor embedded part of the foundation.
Installation:
- on concrete flanged embedded parts of the foundation;
- foundation parameters are determined by the calculation and depend on the area of operation of supports and soil parameters
Operating characteristics
| Climatic modification and placement category (in accordance with GOST 15150-69) | GOST climatic modification.1 |
| Wind region in accordance with SNiP 2.01.07-85 | to III |
| Snowy region according to SNiP 2.01.07-85 | to V |
| Limit length of the suspended wire | to 100 m |
Цена - 1 427 000,00 Руб. (под заказ)

ZANDZ system support of catenary wire lightning protection with two nodes of wire fixation (suspension height - 35 m)
Product item:
The support is made of galvanized steel, 8-sided, conical. The support shank has flange in the bottom part for fixation with the foundation. At the bottom of the support it is equipped with a hatch that provides access to the place of connection of the grounding device. The hatch is closed with a cover, excluding insertion of precipitation and unauthorized entry.
The supply package includes:
- the support of faceted galvanized steel, 36.5 meters high;
- two nodes for the wire fixation with cross- section of 50 mm2placed on the support at the height of 35 meters;
- anchor embedded part of the foundation
Installation:
- on concrete flanged embedded parts of the foundation;
- foundation parameters are determined by the calculation and depend on the area of operation of supports and soil parameters;
Operating characteristics
| Climatic modification and placement category (in accordance with GOST 15150-69) | GOST climatic modification.1 |
| Wind region in accordance with SNiP 2.01.07-85 | to III |
| Снеговой район по СНиП 2.01.07-85 | до V |
| Предельная длина подвешиваемого троса (на один узел) |
до 100 м |
Цена - 1 516 000,00 Руб. (под заказ)

ZANDZ galvanized steel ground wire
Product item:
Lightening protection wire accepts the lightning strike and take it away through the construction of supports into the grounding device.
ZZ-204-001 - is a spirally wire of galvanized steel cables, made in accordance with GOST 3063-80.
ZANDZ wire possesses high mechanical strength, has a low coefficient of expansion (to reduce the slack), and withstands and safely diverts lightning currents.
|
|
|
|
|
|---|---|---|---|
| ZANDZ ZZ-204-001 Galvanized steel ground wire | 50 | 9,1 |
Цена за метр - 158,00 Руб. (под заказ)

Grounding device
To organize the grounding device of the lightning protection system , you can choose one of our solutions:
- ZANDZ Modular grounding - standard solution for all soil types except rocky / ledge rock and permafrost;
- ZANDZ Electrolytic grounding it is used in the so-called "problematic" soils - with high resistivity (permafrost, rock, sand);
- Horizontal conductors made of copper-bonded steel serve to connect the grounding electrodes to each other and to connect them to the supports.
To choose a suitable system of catenary wire lightning protection and calculate the required grounding device, you ca always contact our Technical Centre.