Insulated clamps and holders

We offer you high-quality and aesthetic products of ZANDZ for external insulated lightning protection.

This section contains two types of clamps and holders:

  • Insulated holders and clamps providing an insulation distance of 750 mm; have an insert from the strengthened fiberglass, UV resistant and resistant to other weather impacts.
  • Clamps for mounting an insulated conductor wire to the roof / facade of the building; allow you to securely fix the ZANDZ insulated conductor wire on surfaces of various types.
Insulated clamps and holders

Insulated holder of the conductor wire to the facade/roof

Insulated holder of the conductor wire to the facade/roof

Insulated holder of the conductor wire to the facade/roof

ZZ-212-001holder of the conductor wire has an optimal design, thanks to which it can be used both on the roof and on the facade of the protected building. The holder allows fixing the conductor wire of the lightning protection system at a safe distance of 750 mm from the object's surface, thereby electrical insulation of the external lightning protection is achieved.

  ZZ-212-001
Diameter of the conductor wire: 8 mm
Insulating distance: 750 mm

Insulated holder of the conductor wire on the drainpipe

Insulated holder of the conductor wire on the drainpipe

Insulated holder of the conductor wire on the drainpipe

older-clamp ZZ-212-003 allows you to fix the conductor wire of an isolated lightning protection system on the drainpipe of the protected object.

  ZZ-212-003
Diameter of the conductor wire: 8 mm
Diameter of the drainpipe: 124 - 240 mm
ulating distance 750 mm

Insulated holder for flat roof
Insulated conductor wire holder on concrete base

Insulated conductor wire holder on concrete base

ZANDZ insulated holders on the concrete base allow you to conveniently fix the conductor wire on the flat roof of the protected building, providing an insulating distance of 750 mm. This ensures electrical insulation of the external lightning protection system with the protected building.

  ZZ-212-002
Diameter of the conductor wire: 8 mm
Insulating distance: 750 mm
The weight of the concrete base: 15 kg

Dimensions of the concrete base:

 
Length: 35 mm
Width: 35 mm
Height: 5 mm

Holder of the insulated conductor wire for flat roof

Plastic holder of insulated conductor wire to the roof

Plastic holder of insulated conductor wire to the roof

locking clamp is made of plastic and filled with concrete, so that the drilling of the roof is not required - it is fixed on the roof with its own weight. Designed for mounting ZZ-212-004 insulated conductor wire on a flat roof.

  ZZ-212-004
Outer diameter of the conductor wire: 20,5 mm
Weight of the locking clamp: 0,8 kg
Material of the clamp:

plastic + concrete

Holder of the insulated conductor wire to the roof/facade

Angular holder of insulated conductor wire

Angular holder of insulated conductor wire

The ZANDZ angular holder allows you to conveniently fix the ZZ-214-001 insulated conductor wire on the roof or facade of the building at an angle of 90° to the surface.

 

  ZZ-212-005
Outer diameter of the conductor wire: 20,5 mm
Material: galvanized steel + plastic

Holder of the insulated conductor wire to the roof/facade

Threaded screw holder of the insulated conductor wire

Threaded screw holder of the insulated conductor wire

The ZANDZ threaded screw holder allows you to securely fix the ZZ-214-001 insulated conductor wire on the facade of the building.

  ZZ-212-006
Outer diameter of the conductor wire: 20,5 mm
Material:

galvanized steel + plastic

 

Cap for crimping insulated conductor wire

Cap for crimping insulated conductor wire

Cap for crimping insulated conductor wire

The cap allows you to crimp the ZZ-214-001 insulated conductor wire for further connection to the lightning rod or grounding device.

  ZZ-214-002
Outer diameter of the conductor wire: 20,5 mm