We offer you high quality and aesthetic products for the creation of external lightning protection, manufactured in Poland at the famous GALMAR factory and tested at the research Center of Grounding and Surge protection (ELPC), consisting of:
● Laboratory of overvoltages
● Laboratories of researches and analysis of the effectiveness of grounding systems
● Laboratories for evaluation of corrosion resistance of materials
The section also provides lightning protection products of ZANDZ national trade mark.

You will find two sections below:

Conventional rod lightning rod in the form of a mast with a sharp tip.
Completely made of stainless steel.
| ZZ-201-004 | |
| Height: | 4000 mm (4m) |
| Diameter of the lightning rod: | 38 mm |
| Thickness of the wall: | 2 mm |
| Weight: | 10 kg |
Vertical lightning rod (lightning rod-mast)
.jpg)
Traditional vertical lightning rod in the form of a mast with a sharp tip.
Completely made of stainless steel.
| GL-21101G | |
| Height: | 2000 mm (2m) |
| Diameter of the lightning rod: | 35 mm |
| Thickness of the wall: | 2 mm |
| Weight: | 5 kg |
| GL-21102G | |
| Height: | 3000 mm (3m) |
| Diameter of the lightning rod: | 35 mm |
| Thickness of the wall: | 2 mm |
| Weight: | 7.3 kg |
| GL-21103G | |
| Height: | 4000 mm (4m) |
| Diameter of the lightning rod: | 35 mm |
| Thickness of the wall: | 2 mm |
| Weight: | 10 kg |
| GL-21104G | |
| Height: | 4700 mm (4.7 m) |
| Diameter of the lightning rod: | 35 mm |
| Thickness of the wall: | 2 mm |
| Weight: | 13.8 kg |
| GL-21105G | |
| Height: | 5700 mm (5,7 m) |
| Diameter of the lightning rod: | 35 mm |
| Thickness of the wall: | 2 mm |
| Weight: | 14.8 kg |
ZANDZ Vertical lightning rod 16-20 meters

ZANDZ classic freestanding lightning rods from 16 to 20 m high.
The supply package includes:
- sectional lightning rod of faceted galvanized steel, 16, 18 or 20 meters high;
- Embedded elements under the foundation.
| ZZ-201-016 | |
| Height (H): | 16000 mm (16m) |
| Material of the body frame: | Sheet steel |
| Bottom diameter (D): | 195 mm |
| Diameter of the support flange (A): | 400 mm |
| Center distance between the holes (B): | 300 mm |
| Coating: | Hot zinc |
| Installation wind area: | I – III |
| ZZ-201-018 | |
| Height (H): | 18000 mm (18m) |
| Material of the body frame: | Sheet steel |
| Bottom diameter (D): | 195 mm |
| Diameter of the support flange (A): | 400 mm |
| Center distance between the holes (B): | 300 mm |
| Coating: | Hot zinc |
| Installation wind area: | I – III |
| ZZ-201-020 | |
| Height (H): | 20000 mm (20m) |
| Material of the body frame: | Sheet steel |
| Bottom diameter (D): | 300 mm |
| Diameter of the support flange (A): | 500 mm |
| Center distance between the holes (B): | 400 mm |
| Coating: | Hot zinc |
| Installation wind area: | I – III |
ZANDZ vertical lightning rod 25-35 meters
ZANDZ classic freestanding lightning rods 25 and 35 m high.
The supply package includes:
- sectional lightning rod of faceted galvanized steel, 25 or 35 meters high;
- Embedded elements under the foundation.
| ZZ-201-025 | |
| Height (H): | 25,000 mm (25m) |
| Material of the body frame: | Sheet steel |
| Coating: | Hot zinc |
| Installation wind area: | I – III |
| ZZ-201-035 | |
| Height (H): | 35,000 mm (35m) |
| Material of the body frame: | Sheet steel |
| Coating: | Hot zinc |
| Installation wind area: | I – III |
Air terminal mast on three concrete bases, single-stage cable support

Traditional vertical lightning rod in the form of a pointed mast from 3.5 to 5 meters high.
Mounted on three concrete bases and is fixed by means of a single-stage cable support.
Made of galvanized steel.
| GL-21120 | |
| Height: | 3500 mm (3.5 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 870 mm |
| Weight: | 100 kg |
| GL-21121 | |
| Height: | 4000 mm (4m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 870 mm |
| Weight: | 102 kg |
| GL-21122 | |
| Height: | 4500 mm (4,5 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 870 mm |
| Weight: | 105 kg |
| GL-21123 | |
| Height: | 5000 mm (5.0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 870 mm |
| Weight: | 110 kg |
Air terminal mast on a concrete base

Traditional vertical lightning rod in the form of a pointed mast from 1.5 to 4 meters high.
Made of galvanized steel.
The mast is mounted on a concrete base
| GL-21130 | |
| Height: | 1500 mm (1.5 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 400 mm |
| Weight: | 50 kg |
| GL-21131 | |
| Height: | 2000 mm (2.0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 400 mm |
| Weight: | 55 kg |
| GL-21132 | |
| Height: | 3000 mm (3,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 400 mm |
| Weight: | 60 kg |
| GL-21133 | |
| Height: | 4000 mm (4m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete base: | 500 mm |
| Weight: | 65 kg |
Air terminal-mast for mounting on vertical surfaces (galvanized steel)
.jpg)
Traditional vertical lightning rod in the form of a pointed mast from 1.5 to 3 meters high.
Mounted on vertical surfaces with anchor bolts.
Made of galvanized steel
| GL-21134 | |
| Height: | 1500 mm (1.5 m) |
| Diameter of the lightning rod: | 14 mm |
| Weight: | 5 kg |
| GL-21135 | |
| Height: | 2000 mm (2.0 m) |
| Diameter of the lightning rod: | 14 mm |
| Weight: | 10 kg |
| GL-21136 | |
| Height: | 3000 mm (3,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Weight: | 15 kg |
.
ZANDZ vertical lightning rod 8-14 meters high

ZANDZ classic freestanding lightning rods from 8 to 14 m high.
The supply package includes:
- base of faceted galvanized steel, 6, 8, 10 or 12 meters high;
- spike lightning rod of galvanized steel, 2 meters high;
- fasteners for fixing the lightning rod on the support;
- Embedded elements under the foundation.
| ZZ-201-008 | |
| Total height: | 8000 mm (8 m) |
| Base height (H): | 6000 mm (6 m) |
| Height of the lightning rod part (L): | 2000 mm (2 m) |
| Thickness of the lightning rod wall: | 3-4 mm |
| Flange size K: | 280x280 mm |
| Distance K1: | 200 mm |
| Diameter of the holes d: | 22 mm |
| Weight: | 70 kg |
| ZZ-201-010 | |
| Total height: | 10000 mm (10m) |
| Base height (H): | 8000 mm (8 m) |
| Height of the lightning rod part (L): | 2000 mm (2 m) |
| Thickness of the lightning rod wall: | 3-4 mm |
| Flange size K: | 280x280 mm |
| Distance K1: | 200 mm |
| Diameter of the holes d: | 25.5 mm |
| Weight: | 90 kg |
| ZZ-201-012 | |
| Total height: | 12000 mm (12m) |
| Base height (H): | 10000 mm (10 m) |
| Height of the lightning rod part (L): | 2000 mm (2 m) |
| Thickness of the lightning rod wall: | 3-4 mm |
| Flange size K: | 280x280 mm |
| Distance K1: | 200 mm |
| Diameter of the holes d: | 26 mm |
| Weight: | 133 kg |
| ZZ-201-014 | |
| Total height: | 14000 mm (14m) |
| Base height (H): | 12000 mm (12 m) |
| Height of the lightning rod part (L): | 2000 mm (2 m) |
| Thickness of the lightning rod wall: | 3-4 mm |
| Flange size K: | 310x310 mm |
| Distance K1: | 250 mm |
| Diameter of the holes d: | 26 mm |
| Weight: | 173 kg |
Air terminal- mast on three concrete bases, two-stage cable support
Traditional vertical lightning rod in the form of a pointed mast from 5.5 to 6.5 meters high.
Mounted on three concrete bases and is fixed with the help of a two-stage rope support.
Made of galvanized steel.
| GL-21124 | |
| Height: | 5500 mm (5.5 m) |
| Lightning rod diameter at the base: | 20 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 870 mm |
| Weight: | 115 kg |
| GL-21125 | |
| Height: | 6000 mm (6.0 m) |
| Lightning rod diameter at the base: | 20 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 870 mm |
| Weight: | 117 kg |
| GL-21126 | |
| Height: | 6500 mm (6,5 m) |
| Lightning rod diameter at the base: | 20 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 870 mm |
| Weight: | 120 kg |
Lightning rod-mast on three concrete bases, three-stage rope support
Traditional vertical lightning rod in the form of a pointed mast from 7.0 to 8.0 meters high.
Mounted on three concrete bases and is fixed with the help of a three-stage rope support.
Made of galvanized steel.
| GL-21127 | |
| Height: | 7000 mm (7.0 m) |
| Lightning rod diameter at the base: | 25 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 960 mm |
| Weight: | 125 kg |
| GL-21128 | |
| Height: | 7500 mm (7.5 m) |
| Lightning rod diameter at the base: | 25 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 960 mm |
| Weight: | 130 kg |
| GL-21129 | |
| Height: | 8000 mm (8,0 m) |
| Lightning rod diameter at the base: | 25 mm |
| Diameter of the concrete base: | 400 mm |
| Occupied area size: | r = 960 mm |
| Weight: | 135 kg |
High vertical lightning rod (lightning rod-mast)
Traditional vertical lightning rod of a great height in the form of a spiky mast of octagonal profile.
| GL-21107 | |
| Height: | 6000 mm (6m) |
| Base diameter: | 156 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 38 kg |
| GL-21107 | |
| Height: | 6000 mm (6m) |
| Base diameter: | 156 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 38 kg |
| GL-21108 | |
| Height: | 8000 mm (8 m) |
| Base diameter: | 191 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 50 kg |
| GL-21109 | |
| Height: | 9000 mm (9m) |
| Base diameter: | 191 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 65 kg |
| GL-21110 | |
| Height: | 10000 mm (10m) |
| Base diameter: | 191 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 69 kg |
| GL-21111 | |
| Height: | 12000 mm (12m) |
| Base diameter: | 191 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 93 kg |
| GL-21112 | |
| Height: | 14000 mm (14m) |
| Base diameter: | 191 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 110 kg |
| GL-21113 | |
| Height: | 17000 mm (17m) |
| Base diameter: | 191 mm |
| Thickness of the wall: | 3 mm |
| Weight: | 150 kg |
ZANDZ Fixation for a rod lightning rod ZZ-201-004 to the wall
The fixation allows to mount a rod lightning rod (mast) on the wall / facade of the building.
| ZZ-203-001 | |
| For lightning rods: | ZZ-201-004 |
| Width of the "claws": | 700 mm (0.7 m) |
| Height of the "claws" | 400 mm (0.4 m) |
| Distance to the wall: | 600 mm (0.6 m) |
ZANDZ clamp to the rod lightning rod ZZ-201-004 for down conductors
The clamp allows you to connect the wire down conductor of a diameter of 8 mm to the rod lightning rod ZZ-202-001
| ZZ-202-001 | |
| Diameter of the down conductor: | 8 mm |
| For lightning rods: | ZZ-201-004 |
| Weight: | 0,2 kg |
| Length: | 62 mm |
| Width: | 30 mm |
| Height (including the bolt): | 100 mm |
The holder allows you to fix the vertical lightning rod (mast) to the wall / facade of the building.
| GL-21201 | |
| For lightning rods: | GL-21101G GL-21102G GL-21103G GL-21104G GL-21105G |
| Width of the "claws": | 700 mm (0.7 m) |
| Height of the "claws": | 400 mm (0.4 m) |
| Distance to the wall: | 600 mm (0.6 m) |
The clamp allows you to connect the wire down conductor of a diameter of 8 mm to the lightning-rod mast GL-21101G / GL-21102G / GL-21103G / GL-21104G / GL-21105G.
| GL-20022 | |
| Diameter of the down conductor: | 8 mm |
| For lightning rods: | GL-21101G GL-21102G GL-21103G |
| Weight: | 0,2 kg |
| Length: | 62 mm |
| Width: | 30 mm |
| Height (including the bolt): | 100 mm |
| GL-20023 | |
| Diameter of the down conductor: | 8 mm |
| For lightning rods: | GL-21104G GL-21105G |
| Weight: | 0.43 kg |
| Length: | 70 mm |
| Width: | 40 mm |
| Height (including the bolt): | 100 mm |
ZANDZ Fixation for a rod lightning rod ZZ-201-004 to the chimney
The fixation allows to mount the rod lightning rod (mast) on the chimney / air channel.
| ZZ-203-002 | |
| For lightning rods: | ZZ-201-004 |
| Width of the "claws": | 400 mm (0.4 m) |
| Height of the "claws" | 300 mm (0.3 m) |
| Distance to the wall: | 400 mm (0.4 m) |
The protective base under the concrete foundation
The base is intended to protect the roof during installation of lightning rods on concrete beds
| GL-21213 | |
| Diameter: | 400 mm |
| Thickness | 4 mm |
| Weight: | 0,2 kg |
| GL-21214 | |
| Diameter: | 500 mm |
| Thickness | 4 mm |
| Weight: | 0,2 kg |
Foundation for a vertical high lightning rod (series GL-21107 (-21113))
The holder allows you to fix the high vertical lightning rod (mast) on a horizontal surface.
| GL-21206 | |
| For lightning rods | GL-21107 |
| Weight: | 110 kg |
| GL-21207 | |
| For lightning rods | GL-21108 GL-21109 GL- 21110 GL-21111 GL -21112 |
| Weight: | 250 kg |
| GL-21208 | |
| For lightning rods | GL-21113 |
| Weight: | 450 kg |