Clamp for ground conductor's connection
Product items:
Stainless steel profiled clamp with M10 bolts. It allows to connect the rod with the ground conductor - round wire (cross-section of 28-78 mm²) or tape (up to 40 mm wide).
Safe use of steel and galvanized conductor is possible - for that purpose, there is a gasket inside the clamp, which prevents formation of galvanochemical connection between steel / zinc and copper of the ground rod.
To prevent loosening of threaded joints "bolt-nut" spring washers are used (Grover washers / grover washers) mounted between the clamp surface and the nut.
| For rods D14 | |
| Weight: | 0,312 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 30 mm |
| For rods D17 | |
| Weight: | 0,312 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 30 mm |
| For rods D17 | |
| Weight: | 0,128 kg |
| Length: | 88 mm |
| Width: | 30 mm |
| Height: | 45 mm |
Boltless clamp for the connection of ground rod with the conductor
Product items:
Coppered boltless steel clamp with a sealing sleeve of stainless steel It allows to connect the copper-bonded clutchless ground rod D17 to the grounding conductor - with wire or tape.
The clamp is supplied with the tape that protects the connection from corrosion.
Supply of boltless clamps is carried only upon request.
| For D8 wire mm: | |
| Weight: | 0,12 kg |
| Length: | 70 mm |
| Diameter: | 17 mm |
| For D10 wire mm: | |
| Weight: | 0,11 kg |
| Length: | 70 mm |
| Diameter: | 17 mm |
| For tape 25x4 mm: | |
| Weight: | 0,11 kg |
| Length: | 70 mm |
| Diameter: | 17 mm |
| For tape 30x4 mm: | |
| Weight: | 0,12 kg |
| Length: | 70 mm |
| Diameter: | 17 mm |
One-bolt clamp for connecting round conductor
Product items: GL-10300 /
Bronze curved one-bolt clamp is intended for the connection of the rod with the round ground conductor: with wire or cable.
Supply of bronze one-bolt curved clamps is carried only upon request.
| For rods D12 | GL-10300 |
| Weight: | 0,03 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 50 mm |
| Tape sizes: | 16-70 mm² |
| For rods D17 | |
| Weight: | 0,03 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 50 mm |
| Tape sizes: | 35-95 mm² |
One-bolt clamp for tape connection
Product items: GL-10314 / GL-10306 / GL-10307 / GL-10315 /
Bronze one-bolt curved clamp is intended for the connection of the ground rod with tape.
Supply of bronze one-bolt curved clamps is carried only upon request.
| For rods D12 | GL-10314 | GL-10306 | GL-10307 |
| Weight: | 0,15 kg | 0,15 kg | 0,23 kg |
| Length: | 60 mm | 60 mm | 60 mm |
| Width: | 70 mm | 70 mm | 70 mm |
| Height: | 50 mm | 50 mm | 50 mm |
| Tape sizes: | 26*8 mm | 26*12 mm | 26*20 mm |
| For rods D14 | GL-10315 | ||||
| Weight: | 0,15 kg | 0,15 kg | 0,23 kg | 0,24 m | 0,3 m |
| Length: | 60 mm | 60 mm | 60 mm | 60 mm | 60 mm |
| Width: | 70 mm | 70 mm | 70 mm | 70 mm | 70 mm |
| Height: | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm |
| Tape sizes: | 26*8 mm | 26*12 mm | 26*18 mm | 40*12 mm | 51*8 mm |
| For rods D17 | GL-10316 | GL-10321 | GL-10322 |
| Weight: | 0,15 m | 0,15 m | 0,23 m |
| Length: | 60 mm | 60 mm | 60 mm |
| Width: | 70 mm | 70 mm | 70 mm |
| Height: | 50 mm | 50 mm | 50 mm |
| Tape sizes: | 26*10 mm | 26*12 mm | 26*18 mm |
Arc-shaped clamp for connecting round conductor
Product items:
Bronze curved clamp is intended for the connection of the rod with a round ground conductor: with wire or cable.
Supply of bronze curved clamps is carried only upon request.
| For rods D15-25 | ||
| Weight: | 0,39 kg | 0,39 kg |
| Length: | 80 mm | 80 mm |
| Width: | 70 mm | 70 mm |
| Height: | 40 mm | 40 mm |
| Tape sizes: | 35-185 mm² | 70-300 mm² |
Arc-shaped clamp for connecting tape
Product items:
Bronze arc-shaped clamp is intended for the connection of the ground rod with tape. When connecting the tape perpendicular to the ground rod, the tape width can be from 25 to 40 mm. In addition to the perpendicular connection, the clamp
Supply of bronze curved clamps is carried only upon request.
| For rods D17 | |
| Weight: | 0,39 kg |
| Length: | 80 mm |
| Width: | 70 mm |
| Height: | 40 mm |
| Connection type: | perpendicular |
| Band width: | 25-40 mm |
| For rods D14 | |
| Weight: | 0,39 kg |
| Length: | 80 mm |
| Width: | 70 mm |
| Height: | 40 mm |
| Connection type: |
perpendicular |
|
Tape width at perpendicular connection |
25-40 mm |
|
Tape width at parallelel connection: |
up to 25 mm |
Screw-on clamp for connecting round conductor
Product items:
Brass screw-on clamp for connection threaded ground rods with a round conductor: with wire or cable, cross- section up to 63 mm².
Supply of brass screw-on clamps is carried only upon request.
| For rods D14 | |
| Weight: | 0,12 kg |
| Length: | 80 mm |
| Width: | 25 mm |
| Height: | 25 mm |
| Tape sizes: | up to 63 mm² |
| For rods D17 | |
| Weight: | 0,17 kg |
| Length: | 80 mm |
| Width: | 25 mm |
| Height: | 25 mm |
| Tape sizes: | up to 63 mm² |
Cruciform clamp for conductor's connection
Product items:
Cruciform clamp of stainless steel with M8 bolts. It allows to connect the rod with the ground conductor - by round wire (cross-section of 28-78 mm²) or tape (up to 36 mm wide).
Safe use of steel and galvanized conductor is possible - for that purpose, there is a gasket inside the clamp, which prevents formation of galvanochemical connection between steel / zinc and copper of the ground rod.
Supply of cruciform clamps made of stainless steel is carried only upon request.
| For rods D12/D14 | |
| Weight: | 0,23 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 20 mm |
| Band width: | 36 mm |
| Tape sizes: | 28-78 mm² |
| For rods D17 | |
| Weight: | 0,23 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 20 mm |
| Band width: | 36 mm |
| Tape sizes: | 28-78 mm² |
Straight clamp for tape connection
Product items:
Stainless steel straight clip with M10 bolts. It allows connecting the rod with tape (up to 40 mm wide).
Supply of cruciform clamps made of stainless steel is carried only upon request.
| For rods D12/D14 | |
| Weight: | 0,14 kg |
| Length: | 70 mm |
| Width: | 30 mm |
| Height: | 40 mm |
| Band width: | up to 40 mm |
| For rods D17 | |
| Weight: | 0,14 kg |
| Length: | 70 mm |
| Width: | 30 mm |
| Height: | 40 mm |
| Band width: | up to 40 mm |
Cruciform clamp for the connection of two conductors
Product items:
Cruciform clamp of stainless steel with bolts M10 and M8. It allows connecting two grounding conductor to each other: wire or tape with the conductor by wire or tape.
Supply of cruciform clamps made of stainless steel is carried only upon request.
| Weight: | 0,31 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 20 mm |
| Size of bolts: | M10 |
| Band width: | тХитФдтХитХЫ 40 mm |
| Tape sizes: | 28-78 mm² |
| Weight: | 0,23 kg |
| Length: | 70 mm |
| Width: | 70 mm |
| Height: | 20 mm |
| Size of bolts: | M8 |
| Band width: | тХитФдтХитХЫ 36 mm |
| Tape sizes: | 28-78 mm² |
Curved clamp for the connection of two conductors
Product items:
Curved clamp of stainless steel with M8 bolts. Allows to interconnect two conductors.
Supply of curved clamps made of stainless steel is carried only upon request.
| Для соединения проводников разного типа | |
| Weight: | 0,15 kg |
| Length: | 90 mm |
| Width: | 40 mm |
| Height: | 40 mm |
| Tape sizes: | 28-78 mm² |
| Band width: | up to 40 mm |
| Для соединения полосы с полосой | |
| Weight: | 0,14 kg |
| Length: | 90 mm |
| Width: | 30 mm |
| Height: | 40 mm |
| Band width: | up to 40 mm |
Curved clamp for electrode connection
Product items:
Curved clamp of stainless steel with M8 bolts. It allows connecting two ground electrodes.
Supply of curved clamps made of stainless steel is carried only upon request.
| For rods D12/D14 | |
| Weight: | 0,15 kg |
| Length: | 90 mm |
| Width: | 30 mm |
| Height: | 40 mm |
| For rods D17 | |
| Weight: | 0,14 kg |
| Length: | 90 mm |
| Width: | 30 mm |
| Height: | 40 mm |