Lightning rods to protect large areas

This section provides a list of lightning rods and auxiliary elements suitable for protection of objects occupying a large area. These can be oil and gas facilities, open switchgear and the like. There are mainly two types of lightning rods:

  • Lightning rods and auxiliary elements for installation in the ground;
  • Lightning rods of various heights for installation on a flat roof.

 

Below you will find two sections:

Lightning rods to protect large areas

 

ZANDZ Vertical lightning rod, 16-20 meters high

ZANDZ Vertical lightning rod, 16-20 meters high

ZANDZ Classic freestanding lightning rods with a height from 16 to 20 m.

Package Includes:

  • sectional lightning rod of faceted galvanized steel, 16, 18 or 20 meters high;
  • cast-in elements under the foundation.

 

 
Height (H): 16000 mm (16 m)
Material of the case: Sheet steel
Bottom diameter (D): 195 mm
Diameter of bearing flange (A): 400 mm
Center hole distance (B): 300 mm
Coverage: Hot-galvanized
Wind installation area: I-III

 

 
Height (H): 18000 mm (18 m)
Material of the case: Sheet steel
Bottom diameter (D): 195 mm
Diameter of bearing flange (A): 400 mm
Center hole distance (B): 300 mm
Coverage: Hot-galvanized
Wind installation area: I-III
 
Height (H): 20000 mm (20 m)
Material of the case: Sheet steel
Bottom diameter (D): 300 mm
Diameter of bearing flange (A): 500 mm
Center hole distance (B): 400 mm
Coverage: Hot-galvanized
Wind installation area: I-III
 

ZANDZ Vertical lightning rod, 25-35 meters high

ZANDZ Vertical lightning rod, 25-35 meters high

ZANDZ classic freestanding lightning rods with a height from 25 to 35 m

Package Includes:

  • sectional lightning rod of faceted galvanized steel, 25 or 35 meters high;
  • cast-in elements under the foundation.
 
Height (H): 25000 mm (25 m)
Material of the case: Sheet steel
Coverage: Hot-galvanized
Wind installation area: I-III
 
Высота (H): 35000 mm (35 m)
Material of the case: Sheet steel
Coverage: Hot-galvanized
Wind installation area: I-III
 

Lightning mast on three concrete foundations, one-stage rope support

Lightning mast on three concrete foundations, one-stage rope support

Ordinary vertical lightning rod in the form of a pointed mast with a height from 3.5 to 5 meters.

It is installed on three concrete bases and fixed by means of one-stage rope support.

Made of galvanized steel. 

 
Height: 3500 mm (3,5 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 870 mm
Weight: 100 kg
 
Height: 4000 mm (4,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 870 mm
Weight: 102 kg
 
Height: 4500 mm (4,5 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 870 mm
Weight: 105 kg
 
Height: 5000 mm (5,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 870 mm
Weight: 110 kg
 

Lightning mast on a concrete base

Lightning mast
on a concrete base

Ordinary vertical lightning rod in the form of a pointed mast with a height of 1.5 to 4 meters.

Made of galvanized steel.

The mast is installed on a concrete base. 

 
Height: 1500 mm (1,5 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 400 mm
Weight: 50 kg
 
Height: 2000 mm (2,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 400 mm
Weight: 55 kg
 
Height: 3000 mm (3,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 400 mm
Weight: 60 kg
 
Height: 4000 mm (4,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete base: 500 mm
Weight: 65 kg
 

Strengthened vertical lightning rod, 35 meters high

Strengthened vertical lightning rod, 35 meters high

ZZ-201-035-6 lightning rod has a reinforced structure and is designed for placement in the I-V wind regions. On request it is also possible to install additional equipment - lighting, stairs, etc.

Package Includes:

  • 35 m high sectional galvanized steel lightning rod: sections of 11.5 + 9.5 +10 + 5 meters.
  • cast-in elements under the foundation.

Made of galvanized steel. 

 
Height (H): 35000 mm (35 m)
Weight: not more: 1100 kg
Material of the case: Sheet steel
Coverage: Hot-galvanized
Wind installation area: I-V
 

Support of lightning protection of 35 meters with the platform for service

Support of lightning protection of 35 meters with the platform for service

The ZZ-204-235-6 lightning protection support has a reinforced structure and is designed for placing on it a platform for maintenance, lighting fixtures (placement height is 25 meters) and stairs to them. The stairs are equipped with fences and platforms for rest.

Package Includes:

  • 3-section trunk of a lightning rod made of 25 mm high faceted galvanized steel;
  • lightning tip h = 10 meters;
  • service platform with searchlight fixing brackets - placement height 25 meters;
  • stairs with areas for rest;
  • embedded elements for the foundation.
 
Height (H): 35000 mm (35 м)
Material of the case: Sheet steel
Coverage: Hot-galvanized

ZANDZ Vertical lightning rod, 8-14 meters high

ZANDZ Vertical lightning rod, 8-14 meters high

ZANDZ classic freestanding lightning rods with the height from 8 to 14 m.

Package Includes:

  • foundation of the faceted galvanized steel, 6, 8, 10 or 12 meters high;
  • pointed galvanized steel rod, 2 meters high;
  • fasteners for fixing the lightning rod on the support;
  • embedded elements under the foundation.

 

 
Overall height: 8000 mm (8 m)
Base height (H): 6000 mm (6 m)
The height of the lightning rod part (L): 2000 mm (2 m)
The wall thickness of the lightning rod: 3-4 mm
Flange size K: 280х280 mm
Distance K1: 200 mm
Diameter of holes d: 22 mm
Weight: 70 kg

 

 
Overall height: 10000 mm
(10 m)
Base height (H): 8000 mm
(8 m)
The height of the lightning rod part (L): 2000 mm
(2 m)
The wall thickness of the lightning rod: 3-4 mm
Flange size K: 280х280 mm
Distance K1: 200 mm
Diameter of holes d: 25,5 mm
Weight: 90 kg
 
Overall height: 12000 mm
(12 m)
Base height (H): 10000 mm
(10 m)
The height of the lightning rod part (L): 2000 mm
(2 m)
The wall thickness of the lightning rod: 3-4 mm
Flange size K: 280х280 mm
Distance K1: 200 mm
Diameter of holes d: 26 mm
Weight: 133 kg
 
Overall height: 14000 mm
(14 m)
Base height (H): 12000 mm
(12 m)
The height of the lightning rod part (L): 2000 mm
(2 m)
The wall thickness of the lightning rod: 3-4 mm
Flange size K: 310х310 mm
Distance K1: 250 mm
Diameter of holes d: 26 mm
Weight: 173 kg
 

Lightning mast on three concrete foundations, two-stage rope support

Lightning mast on three concrete foundations, two-stage rope support

Ordinary vertical lightning rod in the form of a pointed mast with a height from 5.5 to 6.5 meters.

It is installed on three concrete bases and fixed by means of two-stage rope support.

Made of galvanized steel.

 

 
Height: 5500 mm (5,5 m)
Diameter of the lightning rod at the base: 20 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 870 mm
Weight: 115 kg
 
Height: 6000 mm (6,0 m)
Diameter of the lightning rod at the base: 20 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 870 mm
Weight: 117 kg
 
Height: 6500 mm (6,5 m)
Diameter of the lightning rod at the base: 20 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 870 mm
Weight: 120 kg
 

 

Lightning mast on three concrete foundations, three-stage rope support

Lightning mast on three concrete foundations, three-stage rope support

Ordinary vertical lightning rod in the form of a pointed mast with a height of 7.0 to 8.0 meters.

It is installed on three concrete bases and fixed by means of three-stage rope support.

Made of galvanized steel.

 

 
Height: 7000 mm (7,0 м)
Diameter of the lightning rod at the base: 25 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 960 mm
Weight: 125 kg
 
Height: 7500 mm (7,5 m)
Diameter of the lightning rod at the base: 25 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 960 mm
Weight: 130 kg
 
Height: 8000 mm (8,0 m)
Diameter of the lightning rod at the base: 25 mm
Diameter of the concrete base: 400 mm
Size of the occupied area: r = 960 mm
Weight: 135 kg
 

Very high vertical lightning rod (lightning mast)

Very high vertical lightning rod (lightning mast)

The ordinary vertical lightning rod of great height in the form of a pointed mast of an octahedral profile.

 

 
Height: 6000 mm (6 m)
Diameter of the base: 156 mm
Wall thickness: 3 mm
Weight: 38 kg
 
Height: 8000 mm (8 m)
Diameter of the base: 191 mm
Wall thickness: 3 mm
Weight: 50 kg
 
Height: 9000 mm (9 m)
Diameter of the base: 191 mm
Wall thickness: 3 mm
Weight: 65 kg
 
Height: 10000 mm (10 m)
Diameter of the base: 191 mm
Wall thickness: 3 mm
Weight: 69 kg
 
Height: 12000 mm (12 m)
Diameter of the base: 191 mm
Wall thickness: 3 mm
Weight: 93 kg
 
Height: 14000 mm (14 m)
Diameter of the base: 191 mm
Wall thickness: 3 mm
Weight: 110 kg
 
Height: 17000 mm (17 m)
Diameter of the base: 191 mm
Wall thickness: 3 mm
Weight: 150 kg
 

Support of rope lightning protection of 40 meters with the service platform

Support of rope lightning protection of 40 meters with the service platform

The support of the ZZ-204-240-6 rope lightning protection has a reinforced structure and is designed both for use as an intermediate and extreme support for the system of rope lightning protection. Also on a support at a height of 25 meters are located a platform for maintenance, lighting fixtures and stairs. The stairs are equipped with fences and platforms for rest.

Package Includes:

  • foundation of the faceted galvanized steel, 41.5 meters high;
  • rope attachment unit, placed on a support at a height of 40 meters;
  • platform for maintenance and lighting fittings, located at a height of 25 meters, the stairs to them;
  • cast-in elements under the foundation.
 
Height (H): 41500 mm (41,5 m)
Material of the case: Sheet steel
Coverage: Hot-galvanized
 

Protective substrate for the concrete base

Protective substrate for the concrete base

The substrate is designed to protect the roof when mounting lightning masts on concrete foundations.

 

 
Diameter: 400 mm
Thickness: 4 mm
Weight: 0,2 kg

 

 
Diameter: 500 mm
Thickness: 4 mm
Weight: 0,2 kg
 

Rope with a set of tension fittings

Rope with a set of tension fittings

Lightning protection rope directly receives a lightning strike and diverts it through the structure of supports to the grounding device.

The rope in ZZ-ST-AC70 consists of a core - galvanized steel wires, and one or more external layers of aluminum wires. It has a cross section of 70 sq. mm.

Package Includes:

  • Rope steel-aluminum section of 70 sq. Mm - 265 meters;
  • Clamps for a rope - 4 pieces;
  • Slack adjusters for rope - 2 pcs.

This complete set is recommended for placement of a rope in two bays.

The base for the vertical high lightning rod (GL-21107 (-21113) series)

The base for the vertical high lightning rod
(GL-21107 (-21113) series)

The holder allows you to fasten a high vertical lightning rod (mast) on a horizontal surface.

 

 
For lightning rods: GL-21107
Weight: 110 kg

 

 
For lightning rods: GL-21108
GL-21109
GL-21110
GL-21111
GL-21112
Weight: 250 kg
 
For lightning rods: GL-21113
Weight: 450 kg

 

 

GALMAR. Voluntary certification

The certificate of conformity ROSS PL.AH66.N00868 for GALMAR grounding and lightning protection:

The certificate1    The certificate2    The certificate3    The certificate4

The certificate5    The certificate6    The certificate7    The certificate8     The certificate9

 

GALMAR elements of lightning protection. Voluntary certification

The certificate of conformity ROSS PL.АГ13.Н03929 for GALMAR grounding protection: 

The certificate10    The certificate11    The certificate12    The certificate13

 

GALMAR. Certification at the territory of the Customs Union

Exemption letter on the absence of the need for mandatory certification of products within the territory of the countries of the Customs Union (including the Republic of Belarus and the Republic of Kazakhstan):

Exemption letter1    Exemption letter2    Exemption letter3    Exemption letter4