ZANDZ vertical lightning rod 8-14 meters high

Product items: ZZ-201-014

Lightning rod is a metal construction, directly perceiving the lightning strike, taking it away from structures located in the protection zone.

This page lists ZANDZ freestanding lightning rods of the height from 8 to 14 m:

  • ZZ-201-008 - 8 meters
  • ZZ-201-010 - 10 meters
  • ZZ-201-012 - 12 meters
  • ZZ-201-014 - 14 meters

The supply package includes:

  • base of faceted galvanized steel, 6, 8, 10 or 12 meters high;
  • spike lightning rod of galvanized steel, 2 meters high;
  • fasteners for fixing the lightning rod on the support;
  • Embedded elements under the foundation.

Installation:

  • on concrete flanged embedded parts of the foundation;
  • foundation parameters are determined by the calculation and depend on the area of operation of supports and soil parameters;

Bottom design:

The support shank is made of a steel sheet 3-4mm thick, eight-sided, tapered, of different heights from 6.0 to 12 m. The support shank has a flange in the bottom part for fixation to the foundation. In the bottom part of the support there is a hatch that provides access to the place of the grounding device connection. The hatch is closed with a cover, excluding insertion of precipitation and unauthorized entry.

Total height: 8000 mm (8 m) 10000 mm (10 m)
Base height (H): 6000 mm (6 m) 8000 mm (8 m)
Height of the lightning rod part (L): 2000 mm (2 m) 2000 mm (2 m)
Thickness of the lightning rod wall: 3-4 mm 3-4 mm
Flange size K: 280х280 mm 280х280 mm
Distance K1: 200 mm 200 mm
Diameter of the holes d: 22 mm 25,5 mm
Weight: 70 kg 90 kg

Total height: 12000 mm (12 m) 14000 mm (14 m)
Height of the mast base (H): 10000 mm (10 m) 12000 mm (12 m)
Height of the lightning rod part (L): 2000 mm (2 m) 2000 mm (2 m)
Thickness of the lightning rod wall: 3-4 mm 3-4 mm
Flange size K: 280х280 mm 310х310 mm
Distance K1: 200 mm 250 mm
Diameter of the holes d: 26 mm 26 mm
Weight: 133 kg 173 kg

Prices:

ZZ-201-008 - 47 730,00 rbl. (upon request)
ZZ-201-010 - 66 720,00 rbl. (upon request)
ZZ-201-012 - 84 650,00 rbl. (upon request)
ZZ-201-014 - 93 200,00 rbl. (upon request)

Вертикальный молниеприёмник мачта ZANDZВертикальный молниеприёмник мачта ZandZ. Основание

Преимущества:

  • производство - РФ;
  • длительный срок эксплуатации;
  • эстетичный внешний вид;
  • высокая антикоррозионная стойкость покрытия (покрытие нанесено методом горячего цинкования по ГОСТ 9.307-89);
  • мачта снабжена лючком для подключения заземляющего устройства;
  • отсутствие растяжек;
  • простота монтажа и установки мачты;
  • в комплект поставки входят закладные под фундамент и все необходимые крепежные элементы.