Lightning rods for installation on the roof

This section contains lightning rods with concrete foundations meant for installation on a flat roof of the protected object.

Depending on the height of the mast, the lightning rod with three foundations has from one to three steps of rope support, which secures it safely.

Lightning rods for installation on the roof

 

The lightning rod of 14 meters for installation on a roof

The lightning rod of 14 meters for installation on a roof

The lightning rod ZANDZ ZZ-201-014-3 is intended for installation on a flat roof of the protected building. The foundation design allows you to provide the necessary stability of the lightning rod without the use of massive weighing materials. That, in its turn, allows to reduce the roof load.

The scope of delivery of the ZZ-201-014-3 includes everything needed for the assembling and installation of a lightning rod:

  • support stand "tripod"
  • main part of the mast;
  • set of fasteners.

 

 
Height (H): 14000 mm (14 m)
Weight less than: 325 kg
Material of the case: steel
Coverage: Hot-galvanized
Wind installation area: I-III

 

 

Lightning mast on three concrete foundations, one-stage rope support

Lightning mast on three concrete foundations, one-stage rope support

An ordinary vertical lightning rod in the form of a pointed mast with the height of 3.5 to 5 meters.

It is installed on three concrete foundations and secured by one-stage rope support.

Made of galvanized steel. 

 
Height: 3500 mm (3,5 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 870 mm
Weight: 100 kg
 
Height: 4000 mm (4,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 870 mm
Weight: 102 kg
 
Height: 4500 mm (4,5 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 870 mm
Weight: 105 kg
 
Height: 5000 mm (5,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 870 mm
Weight: 110 kg
 

Lightning mast on a concrete foundation

Lightning mast
on a concrete foundation

An ordinary vertical lightning rod in the form of a pointed mast with the height of 1.5 to 4 meters.

Made of galvanized steel.

The mast is installed on a concrete foundation.

 

 
Height: 1500 mm (1,5 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 400 mm
Weight: 50 kg
 
Height: 2000 mm (2,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 400 mm
Weight: 55 kg
 
Height: 3000 mm (3,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 400 mm
Weight: 60 kg
 
Height: 4000 mm (4,0 m)
Diameter of the lightning rod: 14 mm
Diameter of the concrete foundation: 500 mm
Weight: 65 kg

Lightning mast on three concrete foundations, two-stage rope support

Lightning mast on three concrete foundations, two-stage rope support

An ordinary vertical lightning rod in the form of a pointed mast with the height of 5.5 to 6.5 meters.

It is installed on three concrete foundations and secured by two-stage rope support.

Made of galvanized steel.

 

 
Height: 5500 mm (5,5 m)
Diameter of the lightning rod at the foundation: 20 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 870 mm
Weight: 115 kg

 

 
Height: 6000 mm (6,0 m)
Diameter of the lightning rod at the foundation: 20 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 870 mm
Weight: 117 kg
 
Height: 6500 mm (6,5 m)
Diameter of the lightning rod at the foundation: 20 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 870 mm
Weight: 120 kg
 

Lightning mast on three concrete foundations, three-stage rope support

Lightning mast on three concrete foundations, three-stage rope support

An ordinary vertical lightning rod in the form of a pointed mast with the height of 7.0 to 8.0 meters.

It is installed on three concrete foundations and secured by three-stage rope support.

Made of galvanized steel.

 

 
Height: 7000 mm (7,0 m)
Diameter of the lightning rod at the foundation: 25 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 960 mm
Weight: 125 kg
 
Height: 7500 mm (7,5 m)
Diameter of the lightning rod at the foundation: 25 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 960 mm
Weight: 130 kg
 
Height: 8000 mm (8,0 m)
Diameter of the lightning rod at the foundation: 25 mm
Diameter of the concrete foundation: 400 mm
Size of the occupied area: r = 960 mm
Weight: 135 kg
 

GALMAR. Voluntary certification

The ROSS PL.AH66.N00868 certificate of conformity for GALMAR grounding and lightning protection:

Voluntary certification1    Voluntary certification2    Voluntary certification3    Voluntary certification4

Voluntary certification5    Voluntary certification6    Voluntary certification7    Voluntary certification8     Voluntary certification9

 

GALMAR lightning protection elements. Voluntary certification

The ROSS PL.АГ13.Н03929 certificate of conformity for GALMAR grounding protection:

GALMAR lightning protection elements1    GALMAR lightning protection elements2    GALMAR lightning protection elements3    GALMAR lightning protection elements4

 

GALMAR. Certification in the countries of the Eurasian Customs Union

Exemption letter on the absence of the need for mandatory certification of products in the territory of the countries of the Customs Union (including the Republic of Belarus and the Republic of Kazakhstan):

Certification in the countries of the Eurasian Customs Union1    Certification in the countries of the Eurasian Customs Union2    Certification in the countries of the Eurasian Customs Union3    Certification in the countries of the Eurasian Customs Union4