This section provides a list of lightning rods and auxiliary elements suitable for the protection of single-family houses and other small buildings.
Below you will find two sections:

Traditional mast rod with a sharp tip.
Made entirely of stainless steel.
| Height: | 4000 mm (4 m) |
| Diameter of the lightning rod: | 38 mm |
| Wall thickness: | 2 mm |
| Weight: | 10 kg |
Lightning mast on three concrete foundations, one-stage rope support
The ordinary vertical lightning rod in the form of a pointed mast with a height of 3.5 to 5 meters.
It is installed on three concrete foundations and fixed by means of one-stage rope support.
Made of galvanized steel.
| Height: | 3500 mm (3,5 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 400 mm |
| Size of the occupied area: | r = 870 mm |
| Weight: | 100 kg |
| Height: | 4000 mm (4,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 400 mm |
| Size of the occupied area: | r = 870 mm |
| Weight: | 102 kg |
| Height: | 4500 mm (4,5 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 400 mm |
| Size of the occupied area: | r = 870 mm |
| Weight: | 105 kg |
| Height: | 5000 mm (5,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 400 mm |
| Size of the occupied area: | r = 870 mm |
| Weight: | 110 kg |
Lightning mast
on a concrete foundation
The ordinary vertical lightning rod in the form of a pointed mast with a height of 1.5 to 4 meters.
Made of galvanized steel.
The mast is installed on a concrete foundation.
| Height: | 1500 mm (1,5 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 400 mm |
| Weight: | 50 kg |
| Height: | 2000 mm (2,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 400 mm |
| Weight: | 55 kg |
| Height: | 3000 mm (3,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 400 mm |
| Weight: | 60 kg |
| Height: | 4000 mm (4,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Diameter of the concrete foundation: | 500 mm |
| Weight: | 65 kg |
Lightning mast for attachment to vertical surfaces (galvanized steel)
The ordinary vertical lightning rod in the form of a pointed mast with a height of 1.5 to 3 meters.
Mounted on vertical surfaces with anchor bolts.
Made of galvanized steel.
| Height: | 1500 mm (1,5 m) |
| Diameter of the lightning rod: | 14 mm |
| Weight: | 5 kg |
| Height: | 2000 mm (2,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Weight: | 10 kg |
| Height: | 3000 mm (3,0 m) |
| Diameter of the lightning rod: | 14 mm |
| Weight: | 15 kg |
ZANDZ decorative lightning rod, 2 m high (stainless steel; fastening to the ridge)
(made in Russia
)
ZANDZ decorative lightning rod is a unique solution to ensure lightning protection of your house and preserve its aesthetic appearance.
Made of stainless steel, covered with black paint.
Fasteners for the ridge are included in the package.
| ZZ-201-002-D | |
| Height: | 2000 mm (2 m) |
| Diameter at the foundation: | 38 mm |
| Material: | stainless steel |
| Fastening: | to the ridge |
Vertical lightning rod (lightning mast)
The ordinary vertical mast rod with a sharp tip.
Made entirely of stainless steel.
| Height: | 2000 mm (2 m) |
| Diameter of the lightning rod: | 35 mm |
| Wall thickness: | 2 mm |
| Weight: | 5 kg |
| Height: | 3000 mm (3 m) |
| Diameter of the lightning rod: | 35 mm |
| Wall thickness: | 2 mm |
| Weight: | 7,3 kg |
| Height: | 4000 mm (4 m) |
| Diameter of the lightning rod: | 35 mm |
| Wall thickness: | 2 mm |
| Weight: | 10 kg |
| Height: | 4700 mm (4,7 m) |
| Diameter of the lightning rod: | 35 mm |
| Wall thickness: | 2 mm |
| Weight: | 13,8 kg |
| Height: | 5700 mm (5,7 m) |
| Diameter of the lightning rod: | 35 mm |
| Wall thickness: | 2 mm |
| Weight: | 14,8 kg |
ZANDZ chimney mount for
ZZ-201-004 lightning rod
The mount allows you to install a lightning rod (mast) on the chimney / duct.
| For lightning rod: | ZZ-201-004 |
| Width of legs: | 700 mm (0,7 m) |
| Height of legs: | 400 mm (0,4 m) |
| Distance to wall: | 600 mm (0,6 m) |
ZANDZ conductor wire clamp for
ZZ-201-004 lightning rod
The clamp allows you to connect a conductor wire with the diameter of 8 mm to a
ZZ-202-001 lightning rod.
| Conductor wire diameter: | 8 mm |
| For lightning rods: | ZZ-201-004 |
| Weight: | 0,2 kg |
| Length: | 62 mm |
| Width: | 30 mm |
| Height (including bolt): | 100 mm |
The holder allows you to attach a vertical lightning rod (mast) to the wall / facade of the building.
| For lightning rods: | GL-21101G GL-21102G GL-21103G GL-21104G GL-21105G |
| Width of legs: | 700 mm (0,7 m) |
| Height of legs: | 400 mm (0,4 m) |
| Distance to wall: | 600 mm (0,6 m) |
Conductor wires clamp for
GL-21101G / GL-21102G / GL-21103G / GL-21104G / GL-21105G lightning masts
The clamp allows you to connect a conductor wire with a diameter of 8 mm to
GL-21101G / GL-21102G / GL-21103G / GL-21104G / GL-21105G lightning mast.
| Diameter of the conductor wire: | 8 mm |
| For lightning rods: | GL-21101G GL-21102G GL-21103G |
| Weight: | 0,2 kg |
| Length: | 62 mm |
| Width: | 30 mm |
| Height (including bolt): | 100 mm |
| Diameter of the conductor wire: | 8 mm |
| For lightning rods: | GL-21104G GL-21105G |
| Weight: | 0,43 kg |
| Length: | 70 mm |
| Width: | 40 mm |
| Height (including bolt): | 100 mm |
ZANDZ chimney mount for
ZZ-201-004 lightning rod
The mount allows you to install a lightning rod (mast) on the chimney / duct.
| For lightning rod: | ZZ-201-004 |
| Width of legs: | 400 mm (0,4 m) |
| Height of legs: | 300 mm (0,3 m) |
| Distance to wall: | 400 mm (0,4 m) |
Chimney mount for GL-21101G / GL-21102G /
GL-21103G / GL-21104G lightning masts
The mount allows you attach a vertical lightning rod (mast) to the chimney / duct.
| For lightning rods: | GL-21101G GL-21102G GL-21103G GL-21104G |
| Width of legs: | 400 mm (0,4 m) |
| Height of legs: | 300 mm (0,3 m) |
| Distance to wall: | 400 mm (0,4 m) |
Protective pad for the concrete foundation
The pad is designed to protect the roof during the lightning masts mounting with concrete foundations on it.
| Diameter: | 400 mm |
| Thickness: | 4 mm |
| Weight: | 0,2 kg |
| Diameter: | 500 mm |
| Thickness: | 4 mm |
| Weight: | 0,2 kg |
GALMAR. Voluntary certification
The certificate of conformity ROSS PL.AH66.N00868 for grounding and lightning protection GALMAR:
GALMAR elements of lightning protection. Voluntary certification
The certificate of conformity ROSS PL.АГ13.Н03929 for grounding protection GALMAR:
GALMAR. Certification in the countries of the Eurasian Customs Union
Exemption letter on the absence of the need for mandatory certification of products in the territory of the countries of the Customs Union (including the Republic of Belarus and the Republic of Kazakhstan):