Regulations referred to in the Decree1)

Current standards2) according to PKN (the Polish Committee for Standardization)

PN-EN 62305-1: 2008 Protection against lightning - Part 1: General principles

PN-EN 62305-1: 2011 Protection against lightning - Part 1: General principles (orig.)

PN-EN 62305-2: 2008 Protection against lightning - Part 2: Risk management

PN-EN 62305-2: 2012 Protection against lightning - Part 2: Risk management (orig.)

PN-EN 62305-3: 2009 Protection against lightning - Part 3: Physical damage to structures and life hazard

PN-EN 62305-3: 2011 Protection against lightning - Part 3: Physical damage to structures and life hazard (orig.)

PN-EN 62305-4: 2009 Protection against lightning - Part 4: Electrical and electronic systems within structures

PN-EN 62305-4: 2011 Protection against lightning - Part 4: Electrical and electronic systems within structures (orig.)

 

PN-EN 62561-1: 2012 Lightning Protection System Components (LPSC) - Part 1: Requirements for connection components (orig.)

 

PN-EN 62561-2: 2012 Lightning Protection System Components (LPSC) - Part 2: Requirements for conductors and earth electrodes (orig.)

 

PN-EN 62561-3: 2012 Lightning Protection System Components (LPSC) - Part 3: Requirements for isolating spark gaps (ISG) (orig.)

 

PN-EN 62561-4: 2011 Lightning protection system components (LPSC) - Part 4: Requirements for conductor fasteners

 

PN-EN 62561-5: 2011Lightning protection system components (LPSC) - Part 5: Requirements for earth electrode inspection housings and earth electrode seals (orig.)

 

PN-EN 62561-6: 2011 Lightning Protection System Components (LPSC) - Part 6: Requirements for lightning strike counters (LSC) (orig.)

 

PN-EN 62561-7: 2012 Lightning Protection System Components (LPSC) - Part 7: Requirements for earthing enhancing compounds (orig.)

 

PN-HD 60364-5-54: 2011 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors (orig.)

PN-HD 60364-5-54: 2010 Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors

PN-EN 50522: 2011Earthing of power installations exceeding 1 kV a.c (orig.)

1) the Decree of the Minister of Infrastructure dated 12 April 2002 on the technical conditions for buildings and their location// Dziennik Ustaw. 2002. No. 75, p. 690.

2) As of 09.01.2013.

 

List overvoltage protection standards

Regulations referred to in the Decree1)

Current standards2) according to PKN (the Polish Committee for Standardization)

PN-IEC 60364-4-442: 1999 Electrical systems at construction sites. Protection for safety. Overvoltage protection. Protection of low-voltage installations against temporary overvoltages due to earth faults in the high-voltage systems

PN-HD 60364-4-442: 2012 Low-voltage electrical installations - Part 4-442: Protection for safety - Protection of low-voltage installations against temporary overvoltages due to earth faults (single phase short circuits) in the high-voltage and low-voltage system (orig.)

PN-IEC 60364-4-443:1999 Electrical systems at construction sites. Protection for safety. Overvoltage protection. Protection from weather and couple-enforcement surge

PN-HD 60364-4-443: 2006 Electrical systems at construction sites - Part: 4-443: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances - Protection against transient overvoltages of atmospheric origin or due to switching (orig.)

PN-IEC 60364-4-444:2001Electrical systems at construction sites. Protection for safety. Overvoltage protection. Protection against electromagnetic interference (EMI) in the systems of construction sites

PN-HD 60364-4-444: 2012 Low-voltage electrical installations - Part 4-444: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances.

PN-IEC 60364-5-534:2003 Electrical systems at construction sites. Selection and installation of electrical equipment. Surge protection devices

PN-HD 60364-5-534: 2012 Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control - Clause 534: Surge protection devices

 

PKN-CLC/TS 61643-12:2007 Low-voltage surge protective devices – Part 12: Surge protectivedevices connected to low-voltage power systems – Selection and application principles (ориг.)

 

PKN-CLC / TS 61643-12: 2007 Low-voltage surge protective devices - Part 12: Surge protective devices connected to low-voltage power systems - Selection and application principles (orig.)

 

PN-EN 61643-11:2006/A11:2007 Surge protection devices connected to low-voltage power distribution systems - Part 11: Performance requirements and testing methods

 

PN-EN 61643-21:2004 + A1:2009 Low-voltage surge protection devices - Part 21: Surge protection devices connected to telecommunications and signaling networks - Performance requirements and testing methods.

 

PN-EN 61643-311:2002 Components for low-voltage surge protection devices - Part 311: Performance requirements and test circuits for gas discharge tubes (GDT)(orig.)

 

PN-EN 61643-321: 2003 Components for low-voltage surge protection devices - Part 321: specifications for avalanche breakdown diodes (ABD) (orig.)

 

PN-EN 61643-331: 2008 Components for low-voltage surge protection devices - Part 331: Performance requirements for metal oxide varistors (MOV)

 

PN-EN 50550: 2011 + AC: 2012 Power frequency overvoltage protective device for household and similar applications (orig.)

 