Driving head for a breaker hammer
Product items:
The head facilitates the process of diving ground rods into the ground and increases the operational safety of both people and tools.
At the installation, the head is fixed to the grounding rod through a coupler. The head sizes are selected in a way so that the driving force does not damage the coupler, i.e. the impact impulse is transmitted directly to the rod passing the coupler.
For rods D14 it is offered to replace the head GL-10802 to ZZ-004-060.
| For rods D12 | |
| Weight: | 0,05 kg |
| Length: | 50 mm |
| Diameter: | 25 mm |
| For rods D14 | GL-10802 |
| Weight: | 0,088 kg |
| Length: | 55 mm |
| Diameter: | 25 mm |
| For rods D17 | |
| Weight: | 0,088 kg |
| Length: | 55 mm |
| Diameter: | 28 mm |
Head for threadless ground rods
Product items:
The head facilitates the process of diving ground rods into the ground and increases the operational safety of both people and tools.
When mounting, the head is attached to the ground rod via the threadless coupler. The head sizes are selected in a way so that the driving force does not damage the coupler, i.e. the impact impulse is transmitted directly to the rod passing the coupler.
Supply of heads for threadless rods is carried out only upon request..
| For threadless rods D12 | |
| Weight: | 0,25 kg |
| Length: | 50 mm |
| Diameter: | 20 mm |
| For threadless rods D14 | |
| Weight: | 0,22 kg |
| Length: | 50 mm |
| Diameter: | 20 mm |
| Для безрезьбовых стержней D17 | |
| Weight: | 0,27 kg |
| Length: | 50 mm |
| Diameter: | 20 mm |
Driving head for copper rods
Product items: GL-10898 / GL-10897
The head facilitates the process of diving ground rods into the ground and increases the operational safety of both people and tools.
The head has no thread. During installation it is installed into the hole in the rod. The head sizes are selected in a way so that the driving force does not damage the coupler, i.e. the impact impulse is transmitted directly to the rod passing the coupler.
Поставка Supply of driving heads for copper rods is carried out only upon request.
| For rods D14/D15/D16 |
GL-10898 |
| Weight: | 0,02 kg |
| Length: | 55 mm |
| Diameter: | 25 mm |
| For rods D20 | GL-10897 |
| Weight: | 0,05 kg |
| Length: | 55 mm |
| Diameter: | 25 mm |
Driving head for clutchless ground rod
Product item:
Driving head of tempered steel is designed to transfer impact energy of a sledgehammer or a jackhammer to the center of the clutchless rod. When mounting it is located in the slotted area of the rod.
Supply of GL-10875 driving heads
| For rods D14 | |
| Weight: | 0,15 kg |
| Length: | 100 mm |
| Diameter: | 9 mm |
| For rods D17 | |
| Weight: | 0,15 kg |
| Length: | 100 mm |