Driving head for a breaker hammer

Driving head

Product items: GL-10801 / GL-10802 / GL-10803

The head facilitates the process of diving ground rods into the ground and increases the operational safety of both people and tools.

At the installation, the head is fixed to the grounding rod through a coupler. The head sizes are selected in a way so that the driving force does not damage the coupler, i.e. the impact impulse is transmitted directly to the rod passing the coupler.
For rods D14 it is offered to replace the head GL-10802 to ZZ-004-060.

For rods D12
Weight: 0,05 kg
Length: 50 mm
Diameter: 25 mm
For rods D14
Weight: 0,088 kg
Length: 55 mm
Diameter: 25 mm
For rods D17
Weight: 0,088 kg
Length: 55 mm
Diameter: 28 mm
 

Head for threadless ground rods

Head for threadless ground rods

Product items: GL-10904 / GL-10905 / GL-10906

The head facilitates the process of diving ground rods into the ground and increases the operational safety of both people and tools.

When mounting, the head is attached to the ground rod via the threadless coupler. The head sizes are selected in a way so that the driving force does not damage the coupler, i.e. the impact impulse is transmitted directly to the rod passing the coupler.

Supply of heads for threadless rods is carried out only upon request..

For threadless rods D12
Weight: 0,25 kg
Length: 50 mm
Diameter: 20 mm
For threadless rods D14
Weight: 0,22 kg
Length: 50 mm
Diameter: 20 mm
Для безрезьбовых стержней D17
Weight: 0,27 kg
Length: 50 mm
Diameter: 20 mm
 

Driving head for copper rods

Driving head for copper rods

Product items: GL-10898 / GL-10897

The head facilitates the process of diving ground rods into the ground and increases the operational safety of both people and tools.

The head has no thread. During installation it is installed into the hole in the rod. The head sizes are selected in a way so that the driving force does not damage the coupler, i.e. the impact impulse is transmitted directly to the rod passing the coupler.

Поставка Supply of driving heads for copper rods is carried out only upon request.

For rods
D14/D15/D16
Weight: 0,02 kg
Length: 55 mm
Diameter: 25 mm
For rods D20
Weight: 0,05 kg
Length: 55 mm
Diameter: 25 mm

 

 

Driving head for clutchless ground rod

Нагель для безмуфтового стержня заземления

Product item: GL-10875 / GL-10885

Driving head of tempered steel is designed to transfer impact energy of a sledgehammer or a jackhammer to the center of the clutchless rod. When mounting it is located in the slotted area of the rod.

Supply of GL-10875 driving headsGL-10875 is carried only only upon request.

For rods D14
Weight: 0,15 kg
Length: 100 mm
Diameter: 9 mm
For rods D17
Weight: 0,15 kg
Length: 100 mm
Diameter: 10 mm